5.IEC 61162-1/2 DATA SENTENCES

IEC 61162-1/2 format data is input or output from the data port COM1-COM6. The table below shows the input/output data specifications.

Transponder

Port

Menu setting

Input/Output

Data format

 

LONG RANGE

Input/Output*

IEC61162-2 (38.4kbps) /

COM1

IEC61162-1 (4800bps)

 

 

EXT DISPLAY

Input/Output*

IEC61162-2 (38.4kbps) /

 

 

IEC61162-1 (4800bps)

 

 

 

COM2

EXT DISPLAY

Input/Output*

IEC61162-2 (38.4kbps) /

IEC61162-1 (4800bps)

 

 

 

COM3

EXT DISPLAY

Input/Output*

IEC61162-2 (38.4kbps) /

IEC61162-1 (4800bps)

 

 

 

 

SENSOR

Input*

IEC61162-2 (38.4kbps) /

 

IEC61162-1 (4800bps)

COM4

 

 

EXT DISPLAY

Input/Output*

IEC61162-2 (38.4kbps) /

 

 

IEC61162-1 (4800bps)

 

 

 

COM5

SENSOR

Input*

IEC61162-2 (38.4kbps) /

IEC61162-1 (4800bps)

 

 

 

 

 

 

IEC61162-2 (38.4kbps) /

COM6

SENSOR

Input*

IEC61162-1 (4800bps)

 

 

 

AD-10

 

 

 

*: See next page for details.

28

Image 34
Contents Uais Transponder 00015008313 Safety Instructions System Configuration Category of the unitsStandard supply Equipment ListsIii Optional supply GPS antenna unit MountingAntenna Units Extending antenna cableHow to attach connector N-P-8DFB VHF antenna Location CablingHorizontal separation distance How to attach the plug M-P-7 3 GPS/VHF combined antennaMounting procedure Installing distributor unit DB-1 Desktop mounting Monitor UnitFlush mounting Type Name Type Code No QtyUais Transponder MountingPower Supply option Pilot Plug optionWiring ConnectionInternal ports of the Transponder Armor Fabrication of cables TTYCS-4 and TTYCS-1Q Cable connection at transponderConnection Fabrication of power cable DPYC-2.5 Changing Ship’s Mains Specifications 200-230 VAC White Black 100-115 VACSetting and Adjustment Setting MMSI, IMO No., Name and Call SignSET Mmsi window Setting GPS Antenna Position Setting I/O Port Setting Ship TypeSetting COM port/PC port Press the ENT key again to display the Mode setting window Mode Speed Long Range Priority setup Priority menuAttaching LAN KIT Option AttachingSetting LAN port for PC network Setting LAN port for Navnet 3D networkContinuous IEC 61162-1/2 Data Sentences TransponderInput data/Sentences Output data/SentencesFor FA-1501 For GPA-017S/GSC-001 For DB-1 For FA-1502 Antenna Cable Set CP20-00300 CP20-00310 Page Page Page Hatai Mar,2707 R.Esumi May 20 Page Jan Apr.2007 R.Esumi Page Page Page Page Transponder Unit