Furuno FA-150 installation manual Safety Instructions

Page 3

SAFETY INSTRUCTIONS

WARNING

ELECTRICAL SHOCK HAZARD

Do not open the equipment unless totally familiar with electrical circuits and service manual.

Only qualified personnel should work inside the equipment.

Turn off the power at the switchboard before beginning the installation.

Fire or electrical shock can result if the power is left on.

Do not install the equipment where it may get wet from rain or water splash.

Water in the equipment can result in fire, electrical shock or damage the equipment.

Be sure that the power supply is compatible with the voltage rating of the equipment.

Connection of an incorrect power supply can cause fire or damage the equipment. The voltage rating of the equipment appears on the label above the power connector.

CAUTION

Observe the following compass safe distances to prevent interference to a magnetic compass:

 

Standard

Steering

 

compass

compass

 

 

 

FA-1501

1.2 m

0.8 m

UAIS Transponder

 

 

 

 

 

FA-1502

0.45 m

0.3 m

Monitor unit

 

 

 

 

 

GVA-100

0.3 m

0.3 m

 

 

 

DB-1

0.3 m

0.3 m

 

 

 

PR-240

0.9m

0.6 m

 

 

 

Attach securely protective

earth to the ship's body.

The protective earth is required to the power supply to prevent electrical shock.

i

Image 3
Contents Uais Transponder 00015008313 Safety Instructions Category of the units System ConfigurationEquipment Lists Standard supplyIii Optional supply Extending antenna cable MountingAntenna Units GPS antenna unitHow to attach connector N-P-8DFB Cabling VHF antenna LocationHorizontal separation distance 3 GPS/VHF combined antenna How to attach the plug M-P-7Mounting procedure Installing distributor unit DB-1 Monitor Unit Desktop mountingFlush mounting Name Type Code No Qty TypeMounting Uais TransponderPilot Plug option Power Supply optionConnection WiringInternal ports of the Transponder Armor Cable connection at transponder Fabrication of cables TTYCS-4 and TTYCS-1QConnection Fabrication of power cable DPYC-2.5 200-230 VAC White Black 100-115 VAC Changing Ship’s Mains SpecificationsSetting MMSI, IMO No., Name and Call Sign Setting and AdjustmentSET Mmsi window Setting GPS Antenna Position Setting Ship Type Setting I/O PortSetting COM port/PC port Press the ENT key again to display the Mode setting window Mode Speed Long Range Priority menu Priority setupAttaching Attaching LAN KIT OptionSetting LAN port for Navnet 3D network Setting LAN port for PC networkContinuous Transponder IEC 61162-1/2 Data SentencesOutput data/Sentences Input data/SentencesFor FA-1501 For GPA-017S/GSC-001 For DB-1 For FA-1502 Antenna Cable Set CP20-00300 CP20-00310 Page Page Page Hatai Mar,2707 R.Esumi May 20 Page Jan Apr.2007 R.Esumi Page Page Page Page Transponder Unit