Schumacher PID-410 Connecting Inverter Cables, Operating Instructions, Inverter connection

Page 10

4.CONNECTING INVERTER CABLES

The inverter and power source must be in the OFF mode.

Make sure you connect your inverter to a 12-volt power supply only.

Inverter connection:

1.Locate the positive and negative plastic terminals located on the back of the inverter and remove the terminal caps completely.

2.Install the positive (red) cable ring lug onto the positive (red) terminal screw. Install the negative (black) cable ring lug onto the negative (black) terminal screw. Tighten each terminal so that the cable cannot come loose.

Connecting inverter cable to a vehicle (100 watts maximum):

1.Remove the cigarette lighter from its outlet.

2.Push the 12-volt power plug firmly into the outlet.

Connecting inverter cables to 12v battery or 12v power source:

1.Keep hands, hair, clothing and jewelry clear of battery terminals.

2.Wear eye protection and clothing protection.

3.Connect the positive (red) inverter terminal cable to the power source positive (+) or battery terminal. Make sure the connection is secure.

4.Connect the negative (black) inverter terminal cable to the power source negative (-) or battery terminal. Make sure the connection is secure.

5.To disconnect the inverter, reverse the above steps.

NOTE: The internal speaker may make a brief “beep” when the inverter is being connected to or disconnected from the 12-volt power source.

Failure to make the correct connections will result in blown fuses and permanent damage to the inverter.

5.OPERATING INSTRUCTIONS

1.Connect the inverter (see “CONNECTING INVERTER CABLES” section.

2.Make sure the device to be operated is turned OFF.

3.Plug the device into the inverter AC outlet.

4.Press and hold the ON/OFF switch to turn the inverter on. (The internal speaker will make a brief “beep”. This is normal.) The Watts LED will glow and the digital display will show .

• 10 •

Image 10
Contents Advertencia Page Table of Contents Índice Sección PàginaTable DES Matières PartiePage Important Safety Instructions Risk of electric shock or fireInverter Features Before Using Your Power InverterPage Operating Instructions Connecting Inverter CablesConnecting inverter cable to a vehicle 100 watts maximum Inverter connectionUsing the USB Port Using the Inverter to Operate a TV or Audio DevicePower Source LED DisplayIf the Inverter Fuse Blows Troubleshooting Specifications Model PID-410 / PIF-410Limited Warranty Replacement PartsModel PID-760 / PIF-760 Page Advertencia Instrucciones Importantes DE Seguridad El riesgo de descarga eléctrica o incendioCaracterísticas DEL Inversor Page Para Conectar LOS Cables DEL Inversor Conexión del InversorInstrucciones DE Operación El uso de Puerto USBFuente DE Energía Muestra DE Luces LED SI SE Quema EL Fusible DEL InversorResolución DE Problemas Problema Causa Posible SolucionProblema Causa Posible Solucion Modelo PID-410 / PIF-410 EspecificacionesPiezas DE Repuesto Modelo PID-760 / PIF-760Garantía Limitada Page Page Risque de choc électrique ou d’incendie Caractéristiques DE L’ONDULEUR Avant D’UTILISER Votre OnduleurPage Connexion DES Càbles DE L’ONDULEUR Connexion de l’onduleurInstructions D’UTILISATION Utilisation du port USBSource D’ALIMENTATION Affichage À DEL SI LE Fusible DE L’ONDULEUR SauteProblème Raison Solution DépannageProblème Raison Solution Modèle PID-410 / PIF-410 10. SpécificationsPiêces DE Rechange Modèle PID-760 / PIF-760Garantie Limitée

PID-410 specifications

The Schumacher PID-410 is a versatile and powerful battery charger and maintainer designed to meet the needs of various consumers, from automotive enthusiasts to casual users. This model stands out in the market for its advanced features and user-friendly design.

One of the main features of the PID-410 is its microprocessor-controlled system, which ensures precise charging and prevents overcharging, thereby prolonging battery life. This intelligent control technology continuously monitors the battery's status and adjusts the charging process accordingly, ensuring optimal performance. The unit is suitable for a wide range of battery types, including standard lead-acid, AGM (Absorbent Glass Mat), and gel batteries.

The PID-410 has a multi-stage charging process, which includes bulk, absorption, and float phases. This allows for rapid initial charging while gradually transitioning to a maintenance mode that keeps the battery topped off without causing damage. The ability to recover deeply discharged batteries also sets the PID-410 apart from many conventional chargers, making it an ideal choice for users with older or neglected batteries.

Safety is a paramount concern with the Schumacher PID-410, and it includes several built-in safety features. Reverse polarity protection ensures the charger does not work if the clamps are connected incorrectly, preventing shorts and potential hazards. Additionally, the unit is equipped with short circuit protection and over-temperature protection, making it a reliable option for both novice and experienced users.

Portability is another significant advantage of the PID-410. Its compact design and lightweight construction make it easy to transport and store, allowing users to take it wherever needed. The easy-to-read LED indicators simplify monitoring the charging status, while its built-in handle enhances convenience.

The Schumacher PID-410 is not just a charger; it also serves as a battery maintainer. This feature means that you can connect it to your battery for extended periods without fear of overcharging. It is perfect for seasonal vehicles, like motorcycles, RVs, or classic cars, ensuring that they remain in good condition during off-seasons.

In conclusion, the Schumacher PID-410 embodies innovative technology, safety features, and user-centric design. Whether you are looking to charge a battery quickly or maintain its health over time, the PID-410 proves to be a reliable choice for all your battery maintenance needs.