Xantrex Technology RS400 manual Operating in Invert Mode

Page 21

Operating in Invert Mode

Operating in Invert Mode

In invert mode, the RS400 powers your appliances using energy from the battery. If the On/Standby switch on both the RS400 and the optional S400 Remote Switch are turned to On ( ), the RS400 automatically supplies your appliances with inverter power if the shore power source fails or becomes disconnected.

To operate the RS400 in invert mode:

1.Disconnect the RS400 from shore power.

2.Turn the On/Standby switch on the RS400 to the On ( ) position. The RS400 Inverter ON light illuminates.

AND

If you have an optional S400 Remote Switch installed, turn the remote switch to On ( ).

The Inverter ON light illuminates on the S400 Remote Switch.

3.Operate your appliances.

Important: The RS400 operates normally without the S400 Remote

Switch installed.

If you are not using the RS400, see “Turning the RS400 to Standby When

Not in Use” on page 2–3.

Recharging Your Batteries When Low Battery Light Illuminates

Low battery

If the Low Battery light illuminates on the RS400 while it is operating,

 

your battery level is low (less than 10.7 volts). As long as the Inverter ON

 

light is illuminated on the RS400, the unit will continue to supply inverter

 

power to your appliances.

 

However, Xantrex highly recommends that you recharge your batteries.

 

Turn off your appliances and recharge your battery. When the Low

 

Battery light turns off (at 12.6 volts), you can restart your appliances. See

 

“Restarting or Operating Multiple Appliances”.

Importance of

Xantrex recommends that you recharge your batteries before they are

recharging

50% discharged. This gives them a much longer life cycle than recharging

 

them when they are almost completely discharged.

More information

For more information about battery chargers and battery monitors, see the

 

Xantrex web site at www.xantrex.com

445-0167-01-01

2–5

Image 21
Contents RS400 Sine Wave Inverter Page RS400 Sine Wave Inverter Date and Revision Purpose ScopeOrganization Conventions Used Acronyms and TerminologyRelated Information General Precautions Important Safety InstructionsFCC Information to the User Explosive Gas PrecautionsContents Specifications Introduction How RS400 Works Premium Power and Ease of UseComprehensive Protection Protection feature This protection feature…Front Panel RS400 FeaturesBack Panel 2Back panel of the RS400 2Back Panel FeaturesOptional Accessory Remote Switch Dimensions of Remote SwitchPart number of Remote Switch Operation 1Front panel of the RS400 Front panel features Front Panel FeaturesTurning the RS400 to Standby When Not in Use Operating the RS400Turning the RS400 to On or to Standby 2S400 Remote Switch Using the S400 Remote SwitchRecharging Your Batteries When Low Battery Light Illuminates Operating in Invert ModeRestarting or Operating Multiple Appliances Recovering from Low Battery Voltage ShutdownTo operate in shore power mode Operating in Shore Power Mode2Status of Indicator Lights Monitoring the Indicator Lights3Resetting After a Fault or Shutdown Resetting After a Fault or ShutdownPage Troubleshooting Front Panel Troubleshooting Reference1Troubleshooting Reference Gfci Specifications Physical Specifications with Projections Electrical SpecificationsRegulatory Approvals Fan Cooling SystemTransfer Circuit Page Warranty Warranty and Product InformationDisclaimer ProductExclusions Return Material Authorization Policy Return ProcedureOut of Warranty Service Purchased From Purchase Date Information About Your SystemIndex IX-2 445-0167-01-01 Page Xantrex Technology Inc