Electrical Specifications
Output power at 12 VDC input |
|
| ||||
• Continuous | 400 VA1, 32 °F to 104 °F | |||||
|
|
|
|
| (0 °C to 40 °C), derated | |
|
|
|
|
| linearly to 300 VA at 122 °F | |
|
|
|
|
| (50 °C) | |
• Surge capacity for 5 seconds | 800 VA | |||||
|
|
|
|
|
| |
Input voltage | 12 VDC nominal | |||||
|
|
|
|
| 10.3 to 15.3 VDC | |
|
|
|
|
|
| |
Output voltage | 120 VAC RMS ± 3 VAC | |||||
|
|
|
|
|
| |
Output frequency | 60 Hz ± 0.05 Hz | |||||
|
|
|
|
|
| |
Output wave form | Sine wave | |||||
|
|
|
|
|
|
|
Total harmonic distortion of output waveform | <3% |
| ||||
|
|
|
|
|
|
|
High battery shutdown | 15.3 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Low battery indication | 10.7 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Low battery shutdown | 10.3 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Maximum efficiency | 88% |
| ||||
|
|
|
|
|
|
|
No load current draw with switch On ( |
| ) |
|
| 1.25 | ADC Maximum |
| ||||||
|
|
|
|
|
|
|
No load current draw with switch set to Standby ( |
| ) | 0 ADC | |||
| ||||||
| ||||||
|
|
|
|
|
| |
Circuit breaker | 7.5 AAC | |||||
|
|
|
|
|
|
|
1The term “watts” has been used throughout the guide to refer to output power. More correctly, the actual unit of power used is “VA”.
Physical Specifications with Projections
Length
Width
Height
Weight
13.5inches (343 mm)
7.36inches (187 mm)
3.27inches (83 mm) 10 lb (4.54 kg)