Xantrex Technology RS400 Electrical Specifications, Physical Specifications with Projections

Page 32

Electrical Specifications

Output power at 12 VDC input

 

 

• Continuous

400 VA1, 32 °F to 104 °F

 

 

 

 

 

(0 °C to 40 °C), derated

 

 

 

 

 

linearly to 300 VA at 122 °F

 

 

 

 

 

(50 °C)

• Surge capacity for 5 seconds

800 VA

 

 

 

 

 

 

Input voltage

12 VDC nominal

 

 

 

 

 

10.3 to 15.3 VDC

 

 

 

 

 

 

Output voltage

120 VAC RMS ± 3 VAC

 

 

 

 

 

 

Output frequency

60 Hz ± 0.05 Hz

 

 

 

 

 

 

Output wave form

Sine wave

 

 

 

 

 

 

 

Total harmonic distortion of output waveform

<3%

 

 

 

 

 

 

 

 

High battery shutdown

15.3

± 0.3 VDC

 

 

 

 

 

 

 

Low battery indication

10.7

± 0.3 VDC

 

 

 

 

 

 

 

Low battery shutdown

10.3

± 0.3 VDC

 

 

 

 

 

 

 

Maximum efficiency

88%

 

 

 

 

 

 

 

 

No load current draw with switch On (

 

)

 

 

1.25

ADC Maximum

 

 

 

 

 

 

 

 

No load current draw with switch set to Standby (

 

)

0 ADC

 

 

 

 

 

 

 

 

Circuit breaker

7.5 AAC

 

 

 

 

 

 

 

1The term “watts” has been used throughout the guide to refer to output power. More correctly, the actual unit of power used is “VA”.

Physical Specifications with Projections

Length

Width

Height

Weight

13.5inches (343 mm)

7.36inches (187 mm)

3.27inches (83 mm) 10 lb (4.54 kg)

A–2

445-0167-01-01

Image 32
Contents RS400 Sine Wave Inverter Page RS400 Sine Wave Inverter Date and Revision Organization PurposeScope Related Information Conventions UsedAcronyms and Terminology Important Safety Instructions General PrecautionsExplosive Gas Precautions FCC Information to the UserContents Specifications Introduction Premium Power and Ease of Use How RS400 WorksProtection feature This protection feature… Comprehensive ProtectionRS400 Features Front Panel2Back panel of the RS400 2Back Panel Features Back PanelPart number of Remote Switch Optional Accessory Remote SwitchDimensions of Remote Switch Operation Front Panel Features 1Front panel of the RS400 Front panel featuresTurning the RS400 to On or to Standby Turning the RS400 to Standby When Not in UseOperating the RS400 Using the S400 Remote Switch 2S400 Remote SwitchOperating in Invert Mode Recharging Your Batteries When Low Battery Light IlluminatesRecovering from Low Battery Voltage Shutdown Restarting or Operating Multiple AppliancesOperating in Shore Power Mode To operate in shore power modeMonitoring the Indicator Lights 2Status of Indicator LightsResetting After a Fault or Shutdown 3Resetting After a Fault or ShutdownPage Troubleshooting Troubleshooting Reference Front Panel1Troubleshooting Reference Gfci Specifications Electrical Specifications Physical Specifications with ProjectionsTransfer Circuit Regulatory ApprovalsFan Cooling System Page Warranty and Product Information WarrantyExclusions DisclaimerProduct Out of Warranty Service Return Material Authorization PolicyReturn Procedure Information About Your System Purchased From Purchase DateIndex IX-2 445-0167-01-01 Page Xantrex Technology Inc