PROBLEM: AC product will not operate, red FAULT light ON.

Possible cause

Remedy

 

 

AC product(s) connected

Use a product with a power

are rated at more than the

rating less than the inverter’s

inverter’s continuous

continuous power rating.

power rating; overload

 

shutdown has occurred.

 

 

 

AC product is rated less

Product exceeds inverter’s

than the inverter’s

surge capability. Use a product

continuous power rating;

with starting surge power

high starting surge has

within the inverter’s capability.

caused overload

 

shutdown.

 

 

 

Battery is discharged.

Recharge battery.

 

 

18

Image 23
Contents XPower Pocket Inverter About Xantrex Date and Revision Contents Specifications Introduction Page Important Safety Information Page Page Page Additional Safety Guidelines Safety Features Inverter Features Using the DC Cable with Cigarette Lighter Plug Using the InverterUsing the DC Cable with Airplane Power Plug Airline Compatibility Operating Guidelines Inverter OperationPage Interference with Electronic Equipment Battery Operating TimeBuzzing sound in audio systems and radios Possible cause Remedy TroubleshootingProblem AC product will not operate, red Fault light on Replacing the Fuse USB Power Output SpecificationsAC Power Output Physical Specifications DC Power SpecificationsWarranty Warranty and ReturnPage Page Page Product DisclaimerExclusions Page Return Material Authorization Policy Return Procedure Out of Warranty Service