Xantrex Technology 800 W, 400 W, 200 W manual Connecting for Loads Under 150 W

Page 19

Connecting for Loads Under 150 W

Follow these steps to connect the 200 W unit or 400 W unit:

1.Place the inverter on a flat surface such as the floor of your vehicle.

2.Make sure that the unit is off by verifying the digital display is off.

3.Take the power cord equipped with the lighter plug (Figure 6) and place the ring terminals over the two cabling terminals on the back of the inverter. (The cabling terminals are shown in Figure 3 and Figure 4.)

CAUTION: Reverse polarity

Power connections of the 12 V DC battery to the Digital Inverter must be positive to positive and negative to negative.

A reverse polarity connection (positive to negative) will blow a fuse in the inverter and may permanently damage the unit. Damage caused by a reverse polarity connection is not covered by your warranty.

CAUTION

Make sure you connect red to red and black to black, and make sure you screw the nuts on tightly.

4.Fasten the positive (red) clamp to the positive battery post, and then fasten the negative (black) clamp to the negative battery post.

15

Image 19
Contents Digital Inverter 200 W, 400 W, 800 W Date and Revision About XantrexTrademarks DisclaimerContents Maintaining Battery Condition Troubleshooting Introduction About This Guide Important Safety Information Page Additional Safety Guidelines AC Front Panel Digital Inverter FeaturesAC Panel of 400 W unit 2B 2A DC Back PanelFan and Ventilation Openings Digital Display Panel Digital Display Top PanelDigital Display Panel Functions Types of Connections Cable Clamps/BatteryProduct Lighter Plug Connection Connections Lighter Plug Cable AccessoriesChoosing a Location Connecting the Digital InverterConnecting for Loads Under 150 W Connecting for Loads Over 150 W Page Page Operating Conditions and Guidelines Operating the Digital InverterShutting the inverter off Operating normal loads Min Max Continuous Surge Rating Product Power RatingOperating loads with high surge requirements Producta Wattsb Unit Wattage of Common AC ProductsInverter Load Sample Appliance Operating Time Maintaining Battery ConditionPage Troubleshooting Buzz in audio systems Common ProblemsTelevision interference Possible Cause Solution Troubleshooting ReferenceProblem Measured inverter output is too low Error Possible Cause Unit Unita SpecificationsLow voltage alarm Warranty Warranty and ReturnTelephone 1 Fax Product DisclaimerExclusions Return Material Authorization Policy Page Return Procedure Other Xantrex Products Out of Warranty Service