Xantrex Technology 200 W, 400 W, 800 W manual Specifications, Unit Unita

Page 35

8 Specifications

Specifications are subject to change without notice.

 

200 W unit

400 W unit

800 W unita

AC output voltage (nominal)

 

120 V AC

 

 

 

 

 

DC input voltage range

 

10.5–15.5 V DC

 

 

 

 

 

 

Maximum continuous AC

160 W

320 W

 

640 W

output power

 

 

 

 

 

 

 

 

 

5 minutes AC output power

200 W

400 W

 

750 W

 

 

 

 

 

Maximum AC output surge

400 W

700 W

 

1200 W

power

 

 

 

 

 

 

 

 

AC output frequency

 

60 ± 1 Hz

 

 

 

 

AC output waveform

 

Modified Sine Wave

 

 

 

 

 

No load current draw

0.3 A

0.3 A

 

0.4 A

(at 12 V input)

 

 

 

 

 

 

 

 

Efficiency (maximum)

 

90%

 

 

 

 

 

 

Ambient operating

 

0–40 °C

32–104 °F

temperature range

 

 

 

 

 

 

 

 

 

Storage temperature

 

-20–60 °C

-4–140 °F

 

 

 

 

 

31

Image 35
Contents Digital Inverter 200 W, 400 W, 800 W Date and Revision About XantrexTrademarks DisclaimerContents Maintaining Battery Condition Troubleshooting Introduction About This Guide Important Safety Information Page Additional Safety Guidelines AC Front Panel Digital Inverter FeaturesAC Panel of 400 W unit 2B 2A DC Back PanelFan and Ventilation Openings Digital Display Panel Digital Display Top PanelDigital Display Panel Functions Product Lighter Plug Connection Connections Cable Clamps/BatteryTypes of Connections Lighter Plug Cable AccessoriesChoosing a Location Connecting the Digital InverterConnecting for Loads Under 150 W Connecting for Loads Over 150 W Page Page Operating Conditions and Guidelines Operating the Digital InverterShutting the inverter off Operating normal loads Min Max Continuous Surge Rating Product Power RatingOperating loads with high surge requirements Producta Wattsb Unit Wattage of Common AC ProductsInverter Load Sample Appliance Operating Time Maintaining Battery ConditionPage Troubleshooting Television interference Common ProblemsBuzz in audio systems Possible Cause Solution Troubleshooting ReferenceProblem Measured inverter output is too low Error Possible Cause Unit Unita SpecificationsLow voltage alarm Warranty Warranty and ReturnTelephone 1 Fax Product DisclaimerExclusions Return Material Authorization Policy Page Return Procedure Other Xantrex Products Out of Warranty Service