WARNING: Shock hazard

Batteries contain corrosive materials and present an electrical shock hazard. To prevent irritation and burns, wear protective eyewear and clothing when you install the inverter or work with the batteries. Take special care to ensure that metal tools and personal metal objects like rings and bracelets do not contact the battery terminals.

Follow these steps to make a direct battery connection:

1.Place the inverter on a flat surface.

2.Make sure that the unit is off by verifying the digital display is off.

CAUTION: Reverse polarity

Power connections of the 12 V DC battery to the Digital Inverter must be positive to positive and negative to negative.

A reverse polarity connection (positive to negative) will blow a fuse in the inverter and may permanently damage the unit. Damage caused by a reverse polarity connection is not covered by your warranty.

3.Take the cables equipped with battery clamps on one end (Figure 7) and place the ring terminals over the two cabling terminals on the back of the inverter. (The cabling terminals are shown in Figure 3 and Figure 4.)

17

Image 21
Contents Digital Inverter 200 W, 400 W, 800 W Trademarks About XantrexDisclaimer Date and RevisionContents Maintaining Battery Condition Troubleshooting Introduction About This Guide Important Safety Information Page Additional Safety Guidelines AC Front Panel Digital Inverter FeaturesAC Panel of 400 W unit 2B 2A DC Back PanelFan and Ventilation Openings Digital Display Panel Digital Display Top PanelDigital Display Panel Functions Cable Clamps/Battery Types of ConnectionsProduct Lighter Plug Connection Connections Lighter Plug Cable AccessoriesChoosing a Location Connecting the Digital InverterConnecting for Loads Under 150 W Connecting for Loads Over 150 W Page Page Operating Conditions and Guidelines Operating the Digital InverterShutting the inverter off Operating normal loads Min Max Continuous Surge Rating Product Power RatingOperating loads with high surge requirements Producta Wattsb Unit Wattage of Common AC ProductsInverter Load Sample Appliance Operating Time Maintaining Battery ConditionPage Troubleshooting Common Problems Buzz in audio systemsTelevision interference Possible Cause Solution Troubleshooting ReferenceProblem Measured inverter output is too low Error Possible Cause Unit Unita SpecificationsLow voltage alarm Warranty Warranty and ReturnTelephone 1 Fax Product DisclaimerExclusions Return Material Authorization Policy Page Return Procedure Other Xantrex Products Out of Warranty Service