Xantrex Technology 450 owner manual Inverter Damage

Page 19

4.Solder or crimp the heavy-duty terminals to the positive and negative wires. Use terminals that mate properly with the battery terminals or existing battery cable clamps.

INVERTER DAMAGE

Reversing the positive and negative battery cables will damage the inverter and will void your warranty.

Before connecting the inverter to the battery, double check the connections: The red wire must be connected to the red terminal on the inverter and the positive (+) terminal on the battery; the black wire must be connected to the black terminal on the inverter and the negative (–) terminal on the battery.

Failure to follow these instructions can damage the unit and/or damage other equipment.

5.Remove the nuts from the DC terminals on the inverter.

6.Place the red ring connector on the red (positive +) DC terminal on the inverter. With star washer in place, screw the red nut on until it is snug. Do not over-tighten.

7.Fasten the positive terminal (red wire) to the positive battery post.

8.Fasten the negative terminal (black wire) to the negative battery post.

9.Place the black ring connector on the black (negative –) DC terminal on the inverter. With star washer in place, screw the black nut on until it is snug. Do not over-tighten.

10.Switch the inverter’s ON/OFF switch to the “ON” position. The green power light comes on, and AC power is available at the outlet.

15

Image 19
Contents XPower Inverter Date and Revision Table of Contents Troubleshooting Introduction XPower 450 featuresElectrical Shock Hazard Important Safety InformationHeated Surface Hazard Explosion and Fire Hazard Make sure the area around the battery is well ventilatedRisk of Damage to Equipment Output is NON-SINUSOIDAL Risk of Damage to the Xpower 450 InverterSafety features AC panel FeaturesDC panel Accessories Choosing a location InstallationTo mount the inverter Mounting the inverterReverse Polarity Damage Using the DC cable with cigarette lighter plugHardwiring the inverter to the battery Using the DC cable clipsShock and Fire Hazard To hardwire the inverter to a 12 V battery Inverter Damage Grounding locations Connecting the chassis groundChassis ground screw To test the Gfci protection Testing the GFCI-protected AC outletOperating statuses OperationInverter operation Battery operating time Battery Operating Times Using vehicle batteries Maintaining Battery ConditionMinimizing power draw Common problems TroubleshootingBuzz in audio systems Possible cause Remedy Troubleshooting referenceProblem Measured inverter output is too low Problem Battery run time is less than expected Consumer hotline Electrical specifications SpecificationsPhysical specifications Warranty Limited WarrantyReturn Material Authorization Policy Out of Warranty Service Page Toll free in North America 1-408-987-6030 direct REV B