Xantrex Technology 450 owner manual To hardwire the inverter to a 12 V battery

Page 18

5 4

+

3

2

1

Figure 1 Hardwiring the inverter to a 12 V battery

1.XPower Inverter 450

2.8 AWG red wire from the positive inverter terminal to the positive battery terminal (via the fuse)

3.60 A automotive or marine fuse

4.12 V battery

5.8 AWG black wire from the negative inverter terminal to the negative battery terminal

To hardwire the inverter to a 12 V battery:

1.Make sure the power inverter’s ON/OFF switch is in the OFF position.

2.Use an 8 AWG (or heavier) wire to a maximum total length of 2 m (6.5').

3.Install a 60 A automotive fuse in the positive (red) wire, close to the end that will attach to the battery.

14

Image 18 Contents
XPower Inverter Date and Revision Table of Contents Troubleshooting XPower 450 features IntroductionImportant Safety Information Electrical Shock HazardHeated Surface Hazard Make sure the area around the battery is well ventilated Explosion and Fire HazardRisk of Damage to the Xpower 450 Inverter Risk of Damage to Equipment Output is NON-SINUSOIDALSafety features Features AC panelDC panel Accessories Installation Choosing a location Mounting the inverter To mount the inverterUsing the DC cable with cigarette lighter plug Reverse Polarity DamageUsing the DC cable clips Hardwiring the inverter to the batteryShock and Fire Hazard To hardwire the inverter to a 12 V battery Inverter Damage Connecting the chassis ground Grounding locationsChassis ground screw Testing the GFCI-protected AC outlet To test the Gfci protectionOperation Operating statusesInverter operation Battery operating time Battery Operating Times Maintaining Battery Condition Using vehicle batteriesMinimizing power draw Troubleshooting Common problemsBuzz in audio systems Troubleshooting reference Possible cause RemedyProblem Measured inverter output is too low Problem Battery run time is less than expected Consumer hotline Specifications Electrical specificationsPhysical specifications Limited Warranty WarrantyReturn Material Authorization Policy Out of Warranty Service Page Toll free in North America 1-408-987-6030 direct REV B