dehydration

cerebrospinal fluid leak, recent cranial surgery, or trauma.

WARNINGS

The entire manual should be read before using the S8 ELITE.

Advice contained in this manual should not supersede instructions given by the prescribing physician.

A patient should not connect a device to the data communication port unless instructed to do so by their health care provider or physician. Only ResMed products are designed to be connected to the data communication port. Connecting other devices could result in injury, or damage to the S8 ELITE device.

The S8 ELITE should only be used with masks (and connectors*) recommended by ResMed, or by a physician or respiratory therapist. A mask should not be used unless the S8 ELITE device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked.

Explanation: The S8 ELITE is intended to be used with special masks (or connectors*) which have vent holes to allow continuous flow of air out of the mask.

When the device is turned on and functioning properly, new air from the device flushes the exhaled air out through the mask vent holes. However, when the device is not operating, insufficient fresh air will be provided through the mask, and the exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can, in some circumstances, lead to suffocation. This applies to most models of CPAP devices.

In the event of power failure or machine malfunction, remove the mask.

The S8 ELITE can be set to deliver pressures up to 20 cm H2O. In the unlikely event of certain fault conditions, pressures up to 30 cm H2O are possible.

If oxygen is used with this device, the oxygen flow must be turned off when the device is not operating.

Explanation: When the CPAP device is not in operation and the oxygen flow is left on, oxygen delivered into the air delivery tubing may accumulate within the CPAP machine enclosure and create a risk of fire. This applies to most types of CPAP machines.

Oxygen supports combustion. Oxygen should not be used while you are smoking or in the presence of an open flame.

Always ensure airflow is being generated by the device before the oxygen supply is turned on.

Always turn the oxygen supply off before stopping the airflow from the device. Note: At a fixed rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on where the oxygen is introduced, the pressure settings, patient breathing pattern, mask selection, and leak rate.

*Ports may be incorporated into the mask or in connectors that are near the mask.

6

Image 7
Contents S8 Elite System S8 Elite Blank Module / Module Vierge / Módulo EN Blanco Contents S8 Elite no Accessories ALL Devices Where Applicable Limited Warranty IndexAbout the S8 Elite IntroductionMedical Information Your ResponsibilityPage Adverse Effects Masks S8 Elite SystemHumidifier AccessoriesResscan Data Card Module Page SET UP the S8 Elite HOW to USE the S8 EliteAssemble the Mask Stopping Treatment Start TreatmentSmartstart Excelnt Using the MASK-FITTING FeatureDefinitions of Mask-Fit Star Rating HOW to Attach a Humidifier Keypad Keys HOW to USE the KeypadHOW to Change the Settings HOW to Change the Expiratory Pressure Relief Setting HOW to USE the Standard MenuHOW to Select the Mask Type Other Viewable Information Settings for mask types MaskUsed HRS HOW to USE the Detailed MenuHOW to Change the Tube Length Settings MenuHOW to ADD a Humidifier or Front CAP Messages on the S8 Elite LCD Results MenuOptions Menu Servicing MenuReplace Page Using a Resscan Data Card Module Using a Blank ModuleS8 Modules Remove the Data Card Using the Data Card to Update SettingsInsert the Data Card Copy Data Onto the Data CardEnglish Page Periodic Cleaning Cleaning and MaintenanceDaily Cleaning Weekly CleaningServicing Replacing the AIR FilterFrequently Asked Questions Can I USE MY S8 Elite if Mains AC Power is not AVAILABLE? Problem Possible Cause Solution TroubleshootingCheck tube High Leak Settings Error Remove Card S8 Elite no Accessories System SpecificationsData Card Symbols Which Appear on the Device ALL Devices Where ApplicableData Card Module RF emissions CISPR11 Group Page Recommended separation distance Separation distance according to frequency of transmitter Product Warranty Period Limited WarrantyPage Index PCB
Related manuals
Manual 39 pages 19.68 Kb Manual 158 pages 44.94 Kb Manual 50 pages 57.93 Kb Manual 88 pages 45.08 Kb Manual 20 pages 25.84 Kb

s8 specifications

The ResMed S8 Escape is a highly regarded CPAP (Continuous Positive Airway Pressure) device designed for the treatment of obstructive sleep apnea. Known for its reliability and user-friendly features, the S8 Escape is part of ResMed’s S8 series, which combines advanced technologies with an emphasis on patient comfort.

One of the standout features of the S8 Escape is its AutoRamp technology, which helps patients gradually transition into their prescribed pressure settings. Instead of starting at the full pressure immediately, AutoRamp begins at a lower pressure, allowing users to fall asleep comfortably before automatically increasing to the prescribed level. This feature significantly improves the overall user experience as it reduces anxiety associated with the use of CPAP devices.

The S8 Escape also boasts a built-in air filter that enhances air quality and protects the device from dust and other particulates. Additionally, the device is designed for whisper-quiet operation, ensuring that users can sleep soundly without the disruption of noise, which can be a common issue with less advanced models. This creates a more peaceful sleeping environment, both for the user and their bed partner.

Another important characteristic of the S8 Escape is its compact design and lightweight build. It is easily portable, making it an ideal choice for both home use and travel. The device also features a user-friendly interface, with a simple LCD screen that displays essential information such as pressure settings and therapy time. This allows users to track their usage and monitor their therapy progress conveniently.

The S8 Escape offers various pressure settings and is compatible with a wide range of masks, ensuring that users can find the right fit for their individual needs. The device’s advanced monitoring capabilities also help in providing feedback on therapy effectiveness, allowing healthcare professionals to adjust settings if necessary.

In summary, the ResMed S8 Escape is a highly functional and patient-friendly CPAP device, featuring advanced technologies designed to enhance the user experience. Its AutoRamp technology, quiet operation, and compact design make it a popular choice among individuals dealing with obstructive sleep apnea.