Graco 311593N important safety instructions Technical Data, Flo 2000/3000/4000 15 ft-lb 20.3 Nm

Page 18

Technical Data

Technical Data

Maximum Working Pressure

E-Flo 1500: 425 psi (2.93 MPa, 29.3 bar)

 

E-Flo 2000: 460 psi (3.22 MPa, 32.2 bar)

 

E-Flo 3000: 330 psi (2.31 MPa, 23.1 bar)

 

E-Flo 4000: 250 psi (1.75 MPa, 17.5 bar)

Maximum Fluid Temperature

150°F (66°C)

Electrical Requirements

European Models: 230/400 Vac, 3 phase, 20 A/15 A

 

North American Models: 230/460 Vac, 3 phase, 20 A/15 A

Ambient Temperature Range

32-104°F (0-40°C)

Maximum Fluid Output

See charts on page 19.

Fluid Inlet and Outlet Size

2 in. Tri-clamp

Gear Reducer Oil Capacity

2 quarts (1.9 liters)

Required Gear Reducer Lubricant

ISO VG220 grade oil (Graco Part No. 288414)

Weight (with motor and 2000 cc lowers)

Pump: 550 lb (249 kg)

Wetted Parts

Lower: see manual 3A0539

 

300 Series SST, CV-75, 17-4 PH SST, PTFE

Electric Motor

E-Flo 1500: 3 HP, 1800 rpm (60 Hz) or 1500 rpm (50 Hz), NEMA

 

182 TC Frame

 

E-Flo 2000/3000/4000: 5 HP, 1800 rpm (60 Hz) or 1500 rpm (50

 

Hz), NEMA 184 TC Frame

Maximum Production Motor Speed

1500 rpm (50 Hz)

 

1800 rpm (60 Hz)

Maximum Motor Torque

E-Flo 1500: 9.1 ft-lb (12.3 N•m)

 

E-Flo 2000/3000/4000: 15 ft-lb (20.3 N•m)

Gear Reduction Ratio

75.16:1

18

311593N

Image 18
Contents Flo4-Ball Piston Pumps Contents Related ManualsMaximum Working Pressure and Pump Operational Limits ModelsFlo 4-Ball Piston Pumps SourceModels Motor ApprovalsComponent Approvals Is Sensor CircuitFire and Explosion Hazard Electric Shock Hazard Overview Flo Electric Circulation PumpHazardous AreaEntrance Overview Ground the System Local Control Box Controls and IndicatorsVariable Frequency Drive VFD 120373 UL/CSA Control BoxFill gear reducer reservoir with oil SetupFlush before using equipment Fill TSL ReservoirsPriming Pressure Relief ProcedureOperation Startup Motor Speed and Flow Chart Equations for each lineClean the Slider Cylinder Collectors MaintenancePreventive Maintenance Schedule Check Gear Reducer Oil LevelFollow Pressure Relief Procedure, FlushingChanging the TSL Technical Data Flo 2000/3000/4000 15 ft-lb 20.3 NmFluid Flow in gpm lpm Graco Standard Warranty Graco Information