Graco 311593N important safety instructions Equations for each line, Motor Speed and Flow Chart

Page 15

Operation

gpm (lpm)

 

30 (114)

 

25

(95)

 

20

(76)

Rate

15

(57)

Flow

 

 

 

10

(38)

 

5

(19)

 

 

0

Pump Cycles per Minute

4

8

12

16

20

24

D

C

B

A

Key:

A750 cc Pumps

B1000 cc Pumps

C1500 cc Pumps

D2000 cc Pumps

0

10

20

30

40

50

60

 

(300)

(600)

(900)

(1200)

(1500)

(1800)

Motor Speed in Hz (rpm)

Equations for each line:

2000 cc

30 x VFD (Hz)

Flow (gpm) = 1.13 x

 

75.16

 

1500 cc

30 x VFD (Hz)

Flow (gpm) = 0.811 x

 

75.16

 

1000 cc

30 x VFD (Hz)

Flow (gpm) = 0.598 x

 

75.16

 

750 cc

30 x VFD (Hz)

Flow (gpm) = 0.406 x

 

75.16

 

FIG. 7: Motor Speed and Flow Chart

311593N

15

Image 15
Contents Flo4-Ball Piston Pumps Related Manuals ContentsSource ModelsFlo 4-Ball Piston Pumps Maximum Working Pressure and Pump Operational LimitsModels Is Sensor Circuit ApprovalsComponent Approvals MotorFire and Explosion Hazard Electric Shock Hazard Flo Electric Circulation Pump OverviewHazardous AreaEntrance Overview Ground the System 120373 UL/CSA Control Box Controls and IndicatorsVariable Frequency Drive VFD Local Control BoxFill TSL Reservoirs SetupFlush before using equipment Fill gear reducer reservoir with oilStartup Pressure Relief ProcedureOperation PrimingEquations for each line Motor Speed and Flow ChartCheck Gear Reducer Oil Level MaintenancePreventive Maintenance Schedule Clean the Slider Cylinder CollectorsFollow Pressure Relief Procedure, FlushingChanging the TSL Flo 2000/3000/4000 15 ft-lb 20.3 Nm Technical DataFluid Flow in gpm lpm Graco Information Graco Standard Warranty