Establish a preventive maintenance schedule based on the equipment’s repair history.

Check Gear Reducer Oil Level

Every day, check the oil level in the sight glass (SG) on the gear reducer, with the motor running. Oil level (with motor running) should fall between top and bottom of the sight glass (SG). Open the fill cap (FC) and fill the gear reducer oil reservoir as required with Graco 288414 Oil (package includes twelve 1 quart bottles). Do not overfill. See FIG. 8.

FC

SG

ti8914a

FIG. 8. Oil Fill

Gear Box and Drive Lubrication

Replace the gear box lubricant after a break-in period of 200,000-300,000 cycles. Order 288414 Replacement Oil.

Following the break-in period, replace the gear box lubri- cant once a year.

See FIG. 9. Every 6 months, lubricate the wrist pin bear- ing (7a) on the connecting rod with 1 shot (1 cc) of 107411 Grease or equivalent, using grease zerk (GZ). Replace both wrist pin bearings annually. Order Wrist Pin Replacement Kit 255216. Lubricate the crank pin bearing (X) annually, using grease zerk (GZ).

NOTE: A faint clicking may be heard while the motor is running. This is normal and is due to necessary clear- ances between the coupler (28), motor shaft, and motor key. If the intensity increases significantly over time, it could indicate the coupler is wearing and should be replaced. Do not open the gear reducer. The gear reducer is not field serviceable beyond the maintenance recommended in this manual

X

GZGZ

7a

ti8717a

FIG. 9. Lubricate Wrist Pin Bearing Every 6 Months

Clean the Slider Cylinder Collectors

Every month, check the slider cylinder collectors for dirt or debris. Remove the 2-piece shield covering the cou- pling assembly. Loosen the three set screws (SS) on the collector (CL). Lower the collector and wipe the inside with a clean, damp cloth. Return the collector to its oper- ating position. Tighten the screws finger tight. Reinstall the shields.

CL

SS

ti9539a

FIG. 10. Slider Cylinder Collector

16

311593N

Image 16
Contents Flo4-Ball Piston Pumps Contents Related ManualsModels Flo 4-Ball Piston PumpsMaximum Working Pressure and Pump Operational Limits SourceModels Approvals Component ApprovalsMotor Is Sensor CircuitFire and Explosion Hazard Electric Shock Hazard Overview Flo Electric Circulation PumpArea HazardousEntrance Overview Ground the System Controls and Indicators Variable Frequency Drive VFDLocal Control Box 120373 UL/CSA Control BoxSetup Flush before using equipmentFill gear reducer reservoir with oil Fill TSL ReservoirsPressure Relief Procedure OperationPriming StartupMotor Speed and Flow Chart Equations for each lineMaintenance Preventive Maintenance ScheduleClean the Slider Cylinder Collectors Check Gear Reducer Oil LevelFlushing Follow Pressure Relief Procedure,Changing the TSL Technical Data Flo 2000/3000/4000 15 ft-lb 20.3 NmFluid Flow in gpm lpm Graco Standard Warranty Graco Information