Graco 311593N Setup, Fill gear reducer reservoir with oil, Fill TSL Reservoirs

Page 13

Setup

Fill gear reducer reservoir with oil

Open the fill cap (FC) and fill the gear reducer oil reser- voir with 2 quarts (1.9 liters) of Graco 288414 Oil (twelve 1 quart bottles). Check the oil level in the sight glass (SG) on the gear reducer housing. Do not overfill. See FIG. 5.

NOTE: 2 quarts brings oil level above sight glass (SG) when off, but level drops when operating.

FC

Setup

Fill TSL Reservoirs

Part No. 206995 Throat Seal Liquid (TSL) carries resi- due from the pump rod into the reservoir. Fill the TSL reservoirs (R) with Graco 206994 Throat Seal Liquid (TSL). See FIG. 6. See Changing the TSL on page 17 for fill instructions.

R

R

SG

ti8914a

FIG. 5. Oil Fill

ti8915b

FIG. 6. Fill TSL Reservoirs

Flush before using equipment

The equipment was tested with Stoddard Solvent, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with solvent, flush the equip- ment with a compatible solvent or water before using the equipment. See Flushing, page 17.

311593N

13

Image 13
Contents Flo4-Ball Piston Pumps Related Manuals ContentsFlo 4-Ball Piston Pumps ModelsMaximum Working Pressure and Pump Operational Limits SourceModels Component Approvals ApprovalsMotor Is Sensor CircuitFire and Explosion Hazard Electric Shock Hazard Flo Electric Circulation Pump OverviewArea HazardousEntrance Overview Ground the System Variable Frequency Drive VFD Controls and IndicatorsLocal Control Box 120373 UL/CSA Control BoxFlush before using equipment SetupFill gear reducer reservoir with oil Fill TSL ReservoirsOperation Pressure Relief ProcedurePriming StartupEquations for each line Motor Speed and Flow ChartPreventive Maintenance Schedule MaintenanceClean the Slider Cylinder Collectors Check Gear Reducer Oil LevelFlushing Follow Pressure Relief Procedure,Changing the TSL Flo 2000/3000/4000 15 ft-lb 20.3 Nm Technical DataFluid Flow in gpm lpm Graco Information Graco Standard Warranty