Setup
3. Setup
AC Power
The
Make sure that you are connecting this product to the proper voltage. To determine the power requirements for the
Refer to the Technical Specifications chart in the Technical Information chapter.
Always connect this product to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire.
The listed current rating indicates the maximum current draw during normal operation. For more information, download the document Sizing the Circuit Breakers from the CHAUVET® website: www.chauvetpro.com.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug The
Connection | Wire (US) | Wire (Europe) | Screw Color (US) |
AC Live | Black | Brown | Yellow or Brass |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
|
|
|
|
Make sure to disconnect the product’s power cord before replacing a blown fuse, and always replace it with a fuse of the same type and rating.
Fuse Replacement 1. Disconnect the product from the power outlet.
2.Using a flat head screwdriver, wedge the tip into the slot of the fuse holder.
3.Pry the safety cap out of the housing to pull out the installed fuse.
4.Remove the blown fuse from the safety cap and replace with a fuse of the exact same type and rating.
5.Insert the fuse holder back in place and reconnect power.
Installed fuse (held by plastic clip)
Safety cap
Spare fuse (inside safety cap)