16.Remove the one-way bleed valve 13 from the body using your fingers or a soft plastic probe. DO NOT use a metal screwdriver or blade since this will scratch the sealing surface against which the bleed valve seals. This scratch may allow water to enter the first stage spring chamber during use.

The sealing surface on the body where the one-way valve seals must be totally clean of deposits. If any deposits remain on the sealing surface after initial cleaning, take a fine abrasive polishing stick and polish the surface to remove deposits (see Photo #7).

17.Blow all residue from the body after polishing.

Photo #7

18.Remove the large O-ring 18 from the body and the large O-ring 20 from the pressure adjusting ring.

19.Inspect all O-rings (other than those discarded because they were found in the Maximus annual service kit # 4000-4). If you notice any cuts, deformities, or abrasion, replace the damaged 0- rings. Otherwise, these static O-rings can be reused in the first stage. Most of the O-rings not found in the service kit are non-moving gaskets with little or no pressure across them. The clean environment created by the Positive Air Purge System (Dry Air Bleed) makes this re-use possible. Clean the O-rings carefully with a lint free rag, and re-lubricate lightly with LTI Christo- Lube® MCG #111, Dow-Corning 111® Silicone grease, Parker O-ring Lube®, or equivalent.

20.If necessary, clean all metal parts of the first stage except the piston in an ultrasonic cleaner or cleaning solution.

Remove the O-rings before cleaning any metal parts; most cleaning solutions can damage the O-ring material. See Section 7.3 for recommendations on cleaning solutions.

21.Remove the regulator parts from the cleaning solution. Blow all internal passageways dry with clean, dry compressed air.

22.The piston O-rings and the moving orifice O-rings move in bores. Inspect these bores for corrosion or wear. If the bores are leaking air because of wear, replace the parts. If some corrosion deposits persist, carefully wipe them away with a plastic scrubbing cloth. Blow any resulting dust out of the regulator parts.

23.Inspect the moving orifice's sealing surface (located at the top edge of the orifice cone). Any

9

Image 12
Contents Regulators First Stage Maximus SRB3600 Item # Catalog # DescriptionTable of Contents Introduction Maximus SRB3600 regulatorSpecifications General Specifications for the SRB3600 Maximus RegulatorFirst Stage Regulator SRB3601 Second Stage Regulator SRB3602Rings Reference Chart Special Features of the Maximus SRB3600 Regulator First Stage FeaturesSecond Stage Features First Stage Procedures Before YOU BeginTools Required for First Stage Servicing Disassembly Of First Stage Photo #1Photo #2 Photo #3 Photo #4Photo #5 Photo #6Photo #7 Assembly of First Stage Testing Of First Stage Before You Begin Testing Dry Air Bleed flow TestIntermediate Pressure Test Second Stage Procedures Disassembly Of Second StageTools Required for Second Stage Serving Page Assembly of Second Stage Page SET-UP of Second Stage Testing Of Second Stage Inhalation effort Exhalation EffortLeak Test External Air Leaks Troubleshooting Regulators Helpful HintsParts Cleaning Recommendations No AIR Coming from DRY AIR Bleed Valve on First StageCommonly Used Cleaning Solutions Handling TipsPre-Dive Checks Post-Dive Care TWO Year Warranty and Maintenance Information Proper Procedure for Warranty PaperworkScheduled Maintenance Second Stage Maximus SRB3602 G010A Ring hose outlet end G011B Ring hose inlet endGoodrich Road Clarence Ctr, New York