Sherwood SRB3600 manual Helpful Hints, Troubleshooting Regulators

Page 23

7.0HELPFUL HINTS

7.1TROUBLESHOOTING REGULATORS

POSSIBLE CAUSE

HIGH INSTALLATION EFFORT AT DEPTH:

a. Inlet filter clogged.

b. No air flowing through the dry air bleed system.

c. High pressure air supply insufficient.

d. Second stage improperly adjusted.

FREE FLOWING:

a. Intermediate pressure too high.

b. Damaged or worn HP piston seat.

c. Damaged or worn HP poppet stem seat.

d. Nicked or corroded orifice sealing.

e. Demand lever in second stage bent too high.

f. Weak spring in second stage.

g. Second stage improperly adjusted.

h. Parts in the second stage have been severely chilled due to repeated purging and have shrunk, allowing air to flow.

WET BREATHING:

a. Improper clearing, or diver diving in total head-down position.

RECOMMENDED ACTION

Replace the filter.

Check the flow rate coming out of the one-way bleed valve 13 . If no or low air flow is detected, clean the flow element in the piston, or replace the piston.

Verify the supply air pressure. Make sure the customer had the tank valve turned all the way on.

Repeat Steps 1 through 12 in Section 6.4,

Set-Up of Second Stage.

Adjust the first stage's outlet pressure to below 150 psig.

Replace seat (p/n 3801-5).

This also gives high intermediate pressure.

Replace seat (p/n 978-9BN).

Dress the orifices in the first and second stages with a polishing stick, or replace the orifices.

Adjust or replace the lever.

Replace the spring.

Repeat Steps 1 through 12 in Section 6.4,

Set-Up of Second Stage.

Allow the second stage to warm up to room temperature. This chilling will not occur in normal diving conditions.

Instruct the diver on proper clearing technique.

20

Image 23
Contents Regulators Item # Catalog # Description First Stage Maximus SRB3600Table of Contents Maximus SRB3600 regulator IntroductionSecond Stage Regulator SRB3602 SpecificationsGeneral Specifications for the SRB3600 Maximus Regulator First Stage Regulator SRB3601Rings Reference Chart Second Stage Features Special Features of the Maximus SRB3600 RegulatorFirst Stage Features Tools Required for First Stage Servicing First Stage ProceduresBefore YOU Begin Photo #2 Disassembly Of First StagePhoto #1 Photo #4 Photo #3Photo #6 Photo #5Photo #7 Assembly of First Stage Dry Air Bleed flow Test Testing Of First Stage Before You Begin TestingIntermediate Pressure Test Tools Required for Second Stage Serving Second Stage ProceduresDisassembly Of Second Stage Page Assembly of Second Stage Page SET-UP of Second Stage Leak Test Testing Of Second Stage Inhalation effortExhalation Effort External Air Leaks Helpful Hints Troubleshooting RegulatorsNo AIR Coming from DRY AIR Bleed Valve on First Stage Parts Cleaning RecommendationsPre-Dive Checks Commonly Used Cleaning SolutionsHandling Tips Post-Dive Care Scheduled Maintenance TWO Year Warranty and Maintenance InformationProper Procedure for Warranty Paperwork G010A Ring hose outlet end G011B Ring hose inlet end Second Stage Maximus SRB3602Goodrich Road Clarence Ctr, New York