American Dynamics manual Connection and Setup of the ADCC1100, Supplied Equipment

Page 12

ADCC1100

Chapter 2: Connection and Setup of the ADCC1100

This chapter describes the power and data connections between the ADCC1100 keyboard and the switching system being used.

Supplied Equipment

The ADCC1100 is supplied with the following equipment and accessories:

Two seven foot, MP-CBL connection cables

One MP-KMI wall-mount keyboard matrix interface

UK cable and plug, USA cable and plug, mainland European cable and plug

MP-PSU power supply unit

One Administrator's Smart Card

The power supply is connected to the jack connector of the MP-KMI network access point. The power supply must be a UL listed, Class 2 type.

Setting the Jumpers for the MP-KMI

The MP-KMI contains six jumper links that must be configured according to figure 2.1. Access to the jumpers is obtained by removing the screw holding the cover in place. The table shows the connectivity of the links in the MP-KMI. For most purposes the links should be left in the 2 and 3 position and this is the default factory setting. The KMI performs a RX / TX cross over between the keyboard and matrix RJ45 connectors in this mode. To remove the cross over (which may be required in certain situations), change links 3 and 4 from the default 2 and 3 linked position, to the 1 and 2 position.

Link

Matrix RJ45 pin

1 and 2 Linked

 

2 and 3 Linked

 

 

 

 

 

Lk1

2

+12v

 

Gnd

Lk2

3

Kbd Pin 3

 

n/c

Lk3

4

Kbd Pin 4

 

Kbd Pin 5

Lk4

5

Kbd Pin 5

 

Kbd Pin 4

Lk5

6

Kbd Pin 6

 

n/c

Lk6

8

+12 v

 

Gnd.

 

 

 

 

 

 

 

GND

Tx

Rx

LK6

LK5

LK3 LK4

LK1 LK2

1

2

3

1

2

3

Figure 2.1: MP-KMI Jumper Settings

6

Image 12
Contents ControlCenterTM Copyright Keyboard Installation and Operation Avertissement Elektromagnetische Kompatibilität Funkfrequenzemissionen Advertencia About the ADCC1100 Keyboard Programming with the ADCC1100 Keyboard Key Features About the ADCC1100 KeyboardADCC1100 Keyboard Overview Page Connection and Setup of the ADCC1100 Setting the Jumpers for the MP-KMISupplied Equipment Installation Connections for Cable Distance of Seven Feet or LessConnections for Cable Distance of Greater than Seven Feet Configuring for MP48, AD1024 or Quicksite Mode Keyboard Access Control Basic OperationsLogging on to the Keyboard Mode Welcome screenPlease Enter PIN Keyboard Menu Navigation Entering DataSelecting Monitors Calling a Camera to View on a MonitorControlling a Camera’s Pan, Tilt and Zoom Controlling Camera FocusControlling the Camera Iris Controlling Camera FlipAuto Iris Calling Presets Shots Running System ToursCalling a Scratch Pad Tour Acknowledging Alarms Calling SalvosSetting the Keyboard Display Brightness Setting the Keyboard Display ContrastAuxiliaries Enabling or Disabling the Keyboard Audible WarningViewing Satellite Sites-Quicksite Mode Viewing Satellite SitesRunning Patterns Selecting and Running a MacroSelecting the Macro Running a MacroOperating a VCR or Digital Recorder VCR Control MenuSetting Presets Programming with the ADCC1100 KeyboardProgramming Dome Patterns Setting Scratch Pad Tours Dome Menu FunctionsNavigating Dome Camera Menus Dome Menu NavigationLocking and Unlocking a Camera Programming MacrosStage 1 Programming the Macro Page and Macro Icon Configure Macro Menu Programming a Macro Page NameStoring the Macro Page Configuration to the Smart Card Programming a Macro IconStage 2 Programming a Macro Example 1 Quick Switch function Advanced MacrosProgramming Smart Cards Reading a Smart CardProgramming a Smart Card Programming a New Smart CardConfiguring Partitions Copying Macro Information from One Smart Card to AnotherPartition Menu Page Matrix Menu Matrix MenuInstaller Functions Setting the Baud RateEnabling Lens Macro Keys Configuring for MP48, AD1024 or Quicksite Mode Quicksite ConfigurationConfiguring Satellite Sites Start EndReading Quicksite Settings on a Smart Card Copying Quicksite Settings from One Smart Card to AnotherAppendix a Monitor Arming Commands Monitor Arming Code Monitor Acronym Command SequenceAppendix B Macro Reference Sheet Keyboard Installation and Operation Appendix C Macro Icon Reference Numbers Keyboard Installation and Operation 100 Appendix D Troubleshooting Problem Check ListAppendix E Specifications Model NumbersIndex Keyboard Installation and Operation Running Multiple Macros Keyboard Installation and Operation Please visit our website for more information