American Dynamics ADCC1100 manual Appendix a Monitor Arming Commands

Page 49

Keyboard Installation and Operation

Appendix A: Monitor Arming Commands

Monitors are armed for alarm call up with codes that specify the following three parameters:

1.The display method (single, dual, or block monitors).

2.The queuing method (sequence or hold).

3.The clearance method (instant, auto, or manual).

To arm a monitor with an ADCC1100 keyboard:

1.Call the monitor to be armed.

2.Press the PROGRAM MODE tab key.

3.Enter the monitor arming code number (see table).

4.Press the F2 soft key.

A keyboard operator can also program any monitor armed for instant or auto clearance, for clearance via manual override. Manual override is enabled or disabled after the arming code is programmed. If enabled, an "A" will appear after the three-letter acronym for the arming code that appears on the monitor status line.

When using the AD1024 matrix switcher/controller system, monitors can be armed through system setup software with a PC interface, or through the AD1024 embedded software with an ADCC1100 keyboard. Following is a table of monitor arming codes and the commands that enable the codes.

Monitor Arming Code

Monitor Acronym

Command Sequence

 

 

 

Display Arming Status

see entries below

300, F2

Single, Sequence, Instant

SSI

301, F2

Single, Sequence, Auto

SSA

302, F2

Single, Sequence, Manual

SSM

303, F2

Single, Hold, Instant

SHI

304, F2

Single, Hold, Auto

SHA

305, F2

Single, Hold, Manual

SHM

306, F2

Block, Sequence, Instant

BSI

307, F2

Block, Sequence, Auto

BSA

308, F2

Block, Sequence, Manual

BSM

309, F2

Block, Hold, Instant

BHI

310, F2

Block, Hold, Auto

BHA

311, F2

Block, Hold, Manual

BHM

312, F2

Dual, Hold, Instant

DHI/DSI*

313, F2

Dual, Sequence, Instant

 

 

Dual, Hold, Auto

DHA/DSA*

314, F2

Dual, Sequence, Auto

 

 

Dual, Hold, Manual

DHM/DSM*

315, F2

Dual, Sequence, Manual

 

 

Disarm Monitor

 

316, F2

Enable Monitor Override

 

317, F2

Disable Monitor Override

 

318, F2

*In dual display applications, the first three-letter acronym is displayed on the hold monitor. The second three-letter acronym is displayed on the sequence monitor.

43

Image 49
Contents ControlCenterTM Copyright Keyboard Installation and Operation Avertissement Elektromagnetische Kompatibilität Funkfrequenzemissionen Advertencia About the ADCC1100 Keyboard Programming with the ADCC1100 Keyboard About the ADCC1100 Keyboard Key FeaturesADCC1100 Keyboard Overview Page Setting the Jumpers for the MP-KMI Connection and Setup of the ADCC1100Supplied Equipment Connections for Cable Distance of Seven Feet or Less InstallationConnections for Cable Distance of Greater than Seven Feet Configuring for MP48, AD1024 or Quicksite Mode Basic Operations Keyboard Access ControlWelcome screen Logging on to the Keyboard ModePlease Enter PIN Entering Data Keyboard Menu NavigationCalling a Camera to View on a Monitor Selecting MonitorsControlling Camera Focus Controlling a Camera’s Pan, Tilt and ZoomControlling Camera Flip Controlling the Camera IrisAuto Iris Running System Tours Calling Presets ShotsCalling a Scratch Pad Tour Calling Salvos Acknowledging AlarmsSetting the Keyboard Display Contrast Setting the Keyboard Display BrightnessAuxiliaries Enabling or Disabling the Keyboard Audible WarningViewing Satellite Sites Viewing Satellite Sites-Quicksite ModeSelecting and Running a Macro Running PatternsRunning a Macro Selecting the MacroVCR Control Menu Operating a VCR or Digital RecorderProgramming with the ADCC1100 Keyboard Setting PresetsProgramming Dome Patterns Dome Menu Functions Setting Scratch Pad ToursDome Menu Navigation Navigating Dome Camera MenusProgramming Macros Locking and Unlocking a CameraStage 1 Programming the Macro Page and Macro Icon Programming a Macro Page Name Configure Macro MenuProgramming a Macro Icon Storing the Macro Page Configuration to the Smart CardStage 2 Programming a Macro Advanced Macros Example 1 Quick Switch functionReading a Smart Card Programming Smart CardsProgramming a New Smart Card Programming a Smart CardCopying Macro Information from One Smart Card to Another Configuring PartitionsPartition Menu Page Matrix Menu Matrix MenuSetting the Baud Rate Installer FunctionsEnabling Lens Macro Keys Quicksite Configuration Configuring for MP48, AD1024 or Quicksite ModeStart End Configuring Satellite SitesCopying Quicksite Settings from One Smart Card to Another Reading Quicksite Settings on a Smart CardMonitor Arming Code Monitor Acronym Command Sequence Appendix a Monitor Arming CommandsAppendix B Macro Reference Sheet Keyboard Installation and Operation Appendix C Macro Icon Reference Numbers Keyboard Installation and Operation 100 Problem Check List Appendix D TroubleshootingModel Numbers Appendix E SpecificationsIndex Keyboard Installation and Operation Running Multiple Macros Keyboard Installation and Operation Please visit our website for more information