7.0 TECHNICAL SPECIFICATIONS

TUBES

 

Preamp:

8 x 12AX7A

Power amp:

1 x 12AX7A, 4 x EL34

INPUTS

 

Instrument:

-26 dB/1 M

Power Amp In:

+2 dB (AMP 1B + AMP 3)/1 M

 

+9 dB (AMP 1A + AMP 2)/1 M

FX -Return:

-10 dB or -20 dB/48 k

OUTPUTS

 

Preamp Out:

+6 dB/47

FX - Send:

+9 dB or +19 dB/2,2 k

Red Box® DI out:

-26 to -10 dB/220

OUTPUT POWER

100 watts into 4, 8, 16

GENERAL DATA

VOLTAGE

220-230 volts AC (European version)

120 volts AC (North American version)

100 volts AC (Japanese version)

MAINS FUSE

2 x T1,6A (220-230V version)

2x T3,15A (120V version)

2 x T4A (100V version)

ANODE FUSE

1 x T500mA

INTERNAL FUSES

2 x T630 mA • 1 x TT15 A

MAX. POWER CONSUMPTION 506 VA

AMBIENT TEMPERATURE RANGE: -10 °C to +35 °C

DIMENSIONS (W x D x H)

Head:

29,4“ x 10,1“ x 13“

 

(748 x 256 x 330 mm)

Stageboard:

18,9“ x 4,9“ x 2,1“

 

(480 x 125 x 52 mm)

WEIGHTS

 

Head:

approx. 48,5 lbs./22 kg

Stageboard:

approx. 6,66 lbs./3 kg

7.0 TECHNISCHE DATEN

RÖHRENTYPEN

 

Vorstufe:

8 x 12AX7A

Endstufe:

1x 12AX7A, 4 x EL34

EINGÄNGE

 

Instrument:

-26 dB/1 M

Power Amp In:

+2 dB (AMP 1B + AMP 3)/1 M

 

+9 dB (AMP 1A + AMP 2)/1 M

FX - Return:

-10 dB or -20 dB/48 k

AUSGÄNGE

 

Preamp Out:

+6 dB/47

FX - Send:

+9 dB or +19 dB/2,2 k

Red Box® DI Out:

-26 to -10 dB/220

AUSGANGSLEISTUNG

100 Watt an 4, 8, 16

ALLGEMEINES

NETZSPANNUNG

220-230 V ~ (europäisches Modell)

120 V ~ (nordamerikanisches Modell)

100 V ~ (japanisches Modell)

NETZSICHERUNG

2x T 1,6 A (europäisches Modell)

2x T 3,15 A (nordamerikanisches Modell)

2 x T4A (japanisches Model)

ANODENSICHERUNG

T 500 mA

INTERNE SICHERUNGEN

2 x T630 mA • 1 x TT15 A

MAX. LEISTUNGSAUFNAHME 506 VA

UMGEBUNGSTEMPERATURBEREICH IM BETRIEB: -10°C bis +35°C

MAßE (B x T x H)

 

Head:

748 x 256 x 330 mm

Stageboard:

480 x 52 x 125 mm

GEWICHTE

 

Head:

ca. 22 kg

Stageboard:

ca. 3 kg

DEUTSCH

ENGLISH

27

Image 27
Contents Watt Tube Amplifier Wichtig Thank YOU for Choosing the Triamp MK Before Powering UP ContentsThree Amps in the Triamp MK AMP 2 Classic British Drive AMP 1 Chunky Clean + FAT Drive CleanAMP 3 Modern Gain Connections and Control FeaturesMaster Section Overview of Control FeaturesFront Preamp SectionFX Loop RearStageboard jack pin assignments Standard SETUP/CABLE Connections Triamp MK II OperationTriamp MK II and Signal Processors Channel SelectionRED BOX DI OUT ALL-TUBE Tone to the Mixer Connecting signal processorsTriamp MK II and Midi Installing the MSM-1 Midi ModuleWhat should you keep in mind When you’re replacing tubes? When is it a good idea To replace tubes?How can you extend the service life Tubes? Troubleshooting Deutsch Dreizehn Röhren FÜR DEN Guten TON VOR DER InbetriebnahmeInhalt AMP 1 Chunky Clean + FAT Drive Clean Netzanschluss UND Wahl DER Netzspannung Anschlüsse UND BedienelementeMaster Sektion Übersicht DER BedienelementeVorderseite Preamp SektionRückseite Pinbelegung der Stageboardbuchse Standard SET UP/VERKABELUNG Bedienung DES Triamp MKDAS Anwählen DER Kanäle DER Triamp MK II MIT EffektgerätenAnschluss DES Effektgerätes RED BOX DI OUT Vollröhre AM MischpultDER Triamp UND Midi Installation des MSM-1 MIDI-ModulsRÖHRENTAUSCH, Wartung UND Pflege Wann ist ein Röhrentausch sinnvoll?Was ist beim Röhrentausch Zu beachten? Wie kann man die Lebensdauer Von Röhren verlängern? FEHLERBESEITIGUNG/TROUBLESHOOTING Der TriAmp MK II lässt sich Nicht einschaltenDer Effektweg ist ungewollt aktiv Technische Daten General DataAllgemeines Hughes & Kettner Triamp MK United states Deutsch English Francais Italiano Español To find a local distributor please visit