Revolabs 02-DSKSYS Using with a Solo Executive Multi-channel System, Charging the Batteries

Page 11

be re-established to its original state, and the beeping will cease. If not, the microphone will turn off.

Using with a Solo Executive Multi-channel System

The Revolabs Solo™ Single Channel Wearable Microphone can be paired to a Solo Executive Multi- channel Wireless Microphone System for users who wish to have a single microphone to use in both the office and in the conference room. This is accomplished by pairing the Single Channel Wearable Microphone to the Executive Multi-channel Base Station and docking the Microphone in the Executive Charger Base. The Microphone can then be used in either system by placing the Microphone in the respective Charger Base for about 5 seconds.

Charging the Batteries

To charge the batteries place the Microphone into the Single Channel Charger Base. During charging, the Microphone status LED indicator changes from solid RED to solid GREEN as charging completes. The Charger Base status indicator remains off during charging. The Microphone is always muted while in the Charger Base. The battery charges from fully depleted to fully charged in approximately two hours, however, it is “quick-charged” to 80% capacity in 45 minutes.

Note: A fully charged battery provides approximately 8 hours of talk time.

When to Charge

Before using the Microphone for the first time, charge for 8 hours or overnight in the Charger Base (until microphone LED turns solid GREEN).

When the Microphone LED begins flashing alternating YELLOW and RED or YELLOW and GREEN, the battery needs recharging. Over time (years), batteries gradually wear down and require charging after a shorter period of use. This is normal.

Important: The Lithium Polymer rechargeable battery that powers the Microphone is not user serviceable. Please see the Revolabs website (www.revolabs.com) for information regarding battery replacement and proper disposal procedures. Warning: Exposing the batteries to fire may result in an explosion.

Setting the Broadcast Power Level

In confined settings where multiple Solo Executive Single Channel systems are used, or where audio interference is likely, it may be necessary to reduce the broadcast power levels.

The broadcast power level between the Microphone and Charger Base can be set to the following three levels.

Highest power level – 60 feet (25M) maximum operating distance between Microphone and Charger Base (default setting).

Medium power level – 20 feet (7M) maximum operating distance between Microphone and Charger Base.

Lowest power level – 6 feet (2M) maximum operating distance between Microphone and Charger Base.

To set the broadcast power level:

Press and hold the Mute button while plugging the USB cable into the Charger Base.

The status LED on the Charger Base will display a sequence of flashes, during which it will flash once, then twice, then three times, where:

1 GREEN flash = full power

2 GREEN flashes = medium power

3 GREEN flashes = low power.

This cycle will repeat 10 times. During any of the cycles, simply release the Mute button immediately after the desired power indication, to set the

18

19

Image 11
Contents Revolabs, Inc Installation and Operation GuideRestricted use with certain medical devices Hearing Aids Table of ContentsFCC User Information and Notice Industry Canada Notice to UsersDsksyseu European Union Usage Restriction Other Medical DevicesExport Law Assurances Dsksys North America Upcs Usage RestrictionRevolabs Solo Single Channel Charger Base IntroductionSystem Components Installing the Solo Single Channel System Page Page Using with Wearable Wireless Microphone Revolabs Solo Wireless MicrophonesUsing with XLR Microphone Wireless Adapter Using with TableTop MicrophonePower/Charging Port docks to all Solo Charger Bases Charging the Batteries Using with a Solo Executive Multi-channel SystemWhen to Charge Setting the Broadcast Power LevelPairing the Microphone to the Charger Base LED Pattern Meaning WarrantyLED Status Indications Solo Single Channel Specifications