Features and Benefits

Quality And Reliability Testing

All Precedentdesigns were rigorously rain tested at the factory to ensure water integrity.

Actual shipping tests were performed to determine packaging requirements. Units were test shipped around the country to determine the best packaging.

Factory shake and drop tests were used as part of the package design process to help assure that the unit arrives at the job site in top condition.

Rigging tests include lifting a unit into the air and letting it drop one foot, assuring that the lifting lugs and rails hold up under stress.

We perform a 100% coil leak test at the factory. The evaporator and condenser coils are leak tested at 1,375 kPa (200 psig) and pressure tested to 3,100 kPa (450 psig).

All parts are inspected at the point of final assembly. Sub-standard parts are identified and rejected immediately.

Every unit receives a 100% unit run test before leaving the production line to make sure it lives up to rigorousTrane requirements.

We test designs at our factory not on our customers!

VariTrac

VariTrac

When Trane’s changeover VAV System for light commercial applications is coupled with Precedent, it provides the latest in technological advances for comfort management systems and can allow thermostat control in every zone served by VariTrac.

8

PKGP-PRC004-EN

Image 8
Contents Packaged Heat Pumps Introduction American Standard Inc. All rights reservedContents Features and Benefits Flexible Applications Easy Access Low Voltage Terminal BoardStandardized Components Micro Controls ReliaTel MicroHinged Access Doors Phase MonitorEconomizer Comm-3/4Trane Communication InterfaceVariTrac Quality And Reliability TestingWe test designs at our factory not on our customers Barometric Relief Condensate TrapClearance Requirements Unit PitchAccessory Selection Cooling Capacity StepHeating Capacity Step Air Delivery SelectionSelection Procedure IP Units Model Number Description 060 11 12,13General Data Table GD-1 General DataTable PD-1a Gross Cooling Capacities MBH WSC060AD,T IP Performance DataTable PD-1 Gross Cooling Capacities kW WSC060AD,T SI Table PD-2 Gross Cooling Capacities kW WSC072AD,T SI Table PD-2a Gross Cooling Capacities MBH WSC072AD,T IPTable PD-3 Gross Cooling Capacities kW WSC090AD,T SI Table PD-3a Gross Cooling Capacities MBH WSC090AD,T IPTable PD-4 Gross Cooling Capacities kW WSC120AD,T SI Table PD-4a Gross Cooling Capacities MBH WSC120AD,T IPPerformance Data At Indicated Indoor Dry Bulb Temp C Performance Data 10.0 10.4 10.2 10.610.4 10.8 10.1 10.6 11.1Nom kW Standard Motor & Hi Static Drive 2 HP Standard Motor & Static Drive2 HP Standard Motor Hi Static DriveNom kW Standard Motor Hi Static Drive Nom kW Standard MotorDrive 2 HP Std Motor & DriveNom kW Standard Motor Drive Nom kW Over-Sized Motor2 HP Std Motor 2 HP Standard Motor Hi Static Drive HP Over-Sized Motor & Hi Static DriveNom kW Standard Motor & Drive Hi Static Drive External Static Pressure Pascals 275 300 325 350 375 M3/h3260 1002 1920 1002Nom kW Std Motor Nom kW Standard Motor Nom kW Over-Sized Motor & Hi Static DriveHP Standard Motor Hi Static Drive HP Standard Motor2400 1051 Nom kW Standard Motor Nom kW OSHP Over-Sized Motor Hi Static Drive Nom kW Standard Motor & Low Static Drive Nom kW Standard Motor & High Static DriveHP Standard Motor & Low Static Drive HP Standard Motor & High Static Drive807 844 HP Std Motor & DriveTable PD-20 Over-Sized Motor & Drive Sheave/Fan Speed RPM Table PD-21 Sound Power Level dB ref -12WattsTable PD-17 Standard Motor & Sheave/Fan Speed RPM Econimizer with OA/RA Dampers23400 4080 3260 4080 4890Table PD-24 Auxiliary Electric Heat Capacity Table PD-24a Auxiliary Electric Heat CapacityVariation From Nominal Airflow Temperature Rise Multiplier Ton3400 M 3/H 4100 M 3/H 5100 M 3/H 6800 M 3/H Stages 10.9 11.3 12.1Controls Integrated Comfort System Sensors availableTable ED-1 Unit Wiring Electrical Data342-456 180-220KW Rating 380 / 415 Volts10.9 13.0 14.4 17.2Volts Phase 380-415108 Compressor Motor Condenser Fan Motor Unit Amps Model NoWires, 24-volts, with Electric Heat Jobsite ConnectionsDimensional DataWSC060DataWSC060 DataWSC072-120 DataWSC072-120 WSC072-120 Roof Curb Accessories WSC060 Barometric Relief DamperDimensional Options WSC072-120Table W-2a Accessory Net Weights1, 2 lbs WeightsTable W-2 Accessory Net Weights1, 2 kg Mechanical Specifications Electric Heaters Roof CurbRemote Potentiometer Manual Outside Air DamperDifferential Pressure Switches COMM3/4Trane Communications InterfaceComm-5 LonTalk Communication Interface Zone SensorsPKGP-PRC004-EN PKGP-PRC004-EN Literature Order Number File Number PL-UN-000-PKGP-PRC004-EN-02-04Supersedes PL-UN-000-PKGP-PRC004-EN-12-03 Stocking Location Webb/Mason 02-04 Electronic Only