iLive AP7141 Work with the channel processing, Access the Preamp, EQ and dynamics, GEQ on faders

Page 15

Step 5 – Work with the channel processing

SEL

PAFL

MUTE

MIX

Channel Processing Block

Due to its compact size, the smaller iLive surfaces do not provide all the physical controls. Access these parameters using the TouchScreen.

*Processing SEL keys

Access the Preamp, EQ and dynamics

Press a strip SEL key. Press the key again to turn it off or press another to access a different channel.

*You can press and hold any SEL key in the Processing Block to temporarily send it to the PAFL system to listen to and meter the signal at that point in the signal path.

The Channel Processing Block displays the current settings for that channel. Controls illuminate if available.

The TouchScreen provides an alternative graphical view and access to the input and insert patching, delay setting and changing the name and colour. Touch the screen to open the different processing views. Touch Return to return to the main page.

Note - To view the processing parameters on the screen make sure all the screen keys are turned off. The SEL keys will not access the processing if you leave the screen in NAME/COLOUR, MIXRACK or SURFACE .

The PREAMP screen lets you patch the Source to the DSP channel, control the remote analogue mic preamp, adjust channel Trim and Polarity, set name and colour, and adjust the HPF (high pass filter).

Choose to present either the preamp controls (Gain, Pad, 48V, Polarity) or trim controls (Trim, Polarity) on the Surface PREAMP section. This lets both FOH and Monitor engineers work with their own independent trim controls once the Gain has been set. All channels may be globally set to present either the Preamp or Trim controls from the MIXRACK SETUP / Mixer Pref screen. Once set, individual channels may be changed from within their PREAMP screen

GEQ on faders

Press a mix master SEL key to access the processing for that master. The GEQ is controlled from the screen or on the faders by pressing the Surface GEQ FADER FLIP key. Press the key to toggle between screen and fader control.

In GEQ on faders mode - The EQ frequencies are indicated on the strip LCDs above. The strip meters display the RTA (PAFL signal if one is selected). The red PK meters display the dominant frequency if this option has been set in the SURFACE / Preferences screen.

The fader on the right becomes the master or currently active send level for the mix. Hold down ALT VIEW to display the EQ dB settings on the strip LCDs. Press the strip SEL keys to reset individual frequency bands to 0dB.

iLive Fixed Format Getting Started Guide

15

AP7141 iss.2

Image 15
Contents Getting Started Guide Safety Instructions System operating firmwareFurther information Table of Contents Systems ILive Series IntroductionIDR-16 System componentsIDR-48 IDR-32Series Control layout PaflIEC Copy/Paste/Reset edit keys Network PL-ANET Connect and power upConnect Surface to MixRack Network settings ACEStatus screen Switch power onBoot up time Status indicatorsRecall the layout for your Surface Customise and save your settingsLoad a ‘Template Show’ as a starting point Load a Template ShowTouchScreen GP, FX, AUX, MTXDCA Surface / Preferences Set your operating preferencesQuick Menu Name and colour channelsChannel Processing view Name & Colour screenAccess the Preamp, EQ and dynamics Work with the channel processingGEQ on faders IEM2 Work with the mixRouting screen WDG1 WDG2 IEM1 IEM2Tap Tempo Work with the FXUsing DCA groups Using DCAs to create Mute GroupsUsing the SoftKeys for Mute Groups Channel Ganging Copy / Paste / ResetPatching Inserts Patch the socketsView and patch channel Input sockets View and patch Output socketsCustomise your configuration To change the MIX BUS configurationTo change the Fader Strip Layout Libraries Save your settingsPower down memory User ProfilesScene memories Show memories Find out more about using the iLive System exampleMonitor System Matrix Main AUX