Akai Ewi4000s manual Parameter Range Defaults Update Control Protocol OFF

Page 48

PARAMETER

RANGE

DEFAULTS

UPDATE

 

 

CONTROL PROTOCOL *

 

 

ON

 

DEFAULT

 

 

OFF

 

 

*CP” (Control Protocol) is set by default to “on,” which adds an extra check to the SysEx data. If you experience problems with SysEx communications, press and hold the SETUP BUTTON, press the HOLD BUTTON or OCTAVE BUTTON until “CP” appears on the PROGRAM / DATA DISPLAY, then release the SETUP BUTTON. Press the HOLD BUTTON or OCTAVE BUTTON so the PROGRAM / DATA DISPLAY reads “OF,” then press the SETUP BUTTON again.

46

Image 48
Contents Reference Manual Page Important Safety Instructions Portable Cart WarningFCC Warning Table of Contents Features IntroductionParts & Functions TOP PanelSide / Rear Panel „ Program / Data Display Section „ Glide Plate Section„ Bend Plate Section „ Cable Clutch SectionPower „ Using Battery Power„ AC adapter Connections Basic Operation Basic Operation„ Note Keys „ Octave Shift Rollers „ Grounding Plates„ Mouthpiece „ Vibrato„ Tonguing „ Pitch Bend PlatesAdjusting the Sensitivity of the Sensors „ Hold Button and Octave Button„ Adjusting the Breath Sensor „ Adjusting the Pitch Bend Sensors„ Adjusting the Vibrato Sensor „ Adjusting the Glide Sensor„ Adjusting the Touch Sensors „ a Note About Adjusting Your SensorsFingering Modes Internal Sound Program KEY Functions„ Selecting the Internal Sounds Program Key „ Assigning a Program Number to a Note Key„ Setting Program Change Preferences „ Recalling the Program Number Assigned to a Note Key„ Program Up with the Hold Button „ Program Down with the Octave ButtonAdjusting the Volumes „ Adjusting the Main Volume„ Adjusting the Volume of Each Program „ Adjusting the Reverb Volume„ Adjusting the Reverb Effect Volume of Each Program „ Adjusting the Delay Effect Volume of Each Program„ Adjusting the Chorus Effect On/Off on Each Program Octave Button Functions „ Assigning Functions to the Octave ButtonHold Button Functions „ Assigning Functions to the Hold Button Pitch Bend Plate Functions Glide Plate Functions„ Assigning Functions to the Pitch Bend Plates „ Assigning Functions to the Glide PlateAdjusting the KEY Delay „ Setting the Glide Effect Time & RateTuning Transpose Function Trans ButtonEditing the Internal Sound with Your Computer About Midi Transmitted Information from the EWI4000s Midi OUT„ Midi Program Change „ Changing the Midi Channel „ Changing the Breath Sensor Output„ Setting the Midi Velocity Value „ Changing the Vibrato Sensor Output to Another Midi Event„ Setting the Hold Function Hold Button on Midi Transmit „ Setting the Glide Plate Function on Midi Transmit„ Sending a Midi Panic Message to Reset All Controllers „ Sending an All Notes Off MessageRestoring the Factory Presets Level master Level preset Reverb masterMiscellaneous Notes EVI Fingerings„ The Right Hand „ The Left HandSoftware Updating „ Basic EVI FingeringsTroubleshooting Fingering Charts Octave Shift RollersEWI Fingerings Saxophone Fingerings Flute Fingerings Oboe Fingerings EVI Fingerings Midi Implementation Chart Transmit/Export Recognize/Import RemarksMenu Structure OctaveGlide Parameter Range Defaults Update Control Protocol OFF Specifications Sound ModulePage