7.6 Monitoring
The SONOSAX
The left most Monitor section (the Main Monitor) is dedicated to the sound engineer working on the mixer. The upper rotary switch selects the source for the phone output, the monitor output and the
The lower rotary switch changes the listening mode ( mono
The two additional middle and right most monitor sections are available for independent remote monitoring and communication purposes, both having an separate communication system ( Private Lines ). They can be used to return different monitoring selections to e.g. the boom operator and the director/producer while on location recording, or to a speaker cabin and to the video control room in broadcasting applications.
7.6.1 Monitor Source Selector
The upper three rotary switches select the source to be monitored:
AUX
AUX
7.6.2 Monitor Mode selector
The lower three rotary switches define the listening mode of the selected source:
RET : | monitors the after fader stereo mix of the 8 Return tracks |
ODD : | the odd channel only of the selected stereo source is monitored in Mono |
EVEN : | the even channel only of the selected stereo source is monitored in Mono |
ST : | the selected source is monitored in stereo |
M : | the selected stereo source is summed in Mono to easily check the Mono compatibility and |
| to detect phase errors |
MS: | decode a MS signal for monitoring purposes. |
The decoder is for monitoring purpose only and does not affect the main. The
NOTE: in Odd, Even and Mono modes, the signal is monitored in mono on both left and right sides.
7.6.3 Phones Level 1 to 3
Set the level of the corresponding monitor output (1 to 3) from - infinite (Mute) to +15 dBu
7.7 Communication and Private Lines
The
COM : talk to all communications lines, incl. PL and PL2
PL1 : talk to second monitor section
PL2 : talk to third monitor section
An external electret or condenser microphone must be connected to the 5 pin binder COM connector. The Talkback/Slate is using the same microphone. (see connectors section for pin assignment )
NOTE: The internal switch S3 selects the mic. powering voltage: 48V phantom or 6VDC for electret
7.7.1 Mic 1 to 3
Adjust the send level of the external Communication/Slate microphone that will be fed into the respective COM, PL1 or PL2 lines. from - infinite (Mute) to +10 dB.
page 26 |