Agilent Technologies 60501B manual Range

Page 7

 

Table 60501-1 Specifications and Supplemental Characteristics (continued)

Current Slew Rate:*

 

 

 

Rate # 30 A Range Step

3 A Range Step

Transition Time

1

0.5

A/ms

0.05

A/s

8.0 ms

2

1.2

A/ms

0.12

A/s

3.2 ms

3

2.5

A/ms

0.25

A/ms

1.6 ms

4

5 A/ms

0.5 A/ms

800 μs

5

12 A/ms

1.2 A/ms

320 μs

6

25 A/ms

2.5 A/ms

160 μs

7

0.05 A/μs

5 A/ms

80 μs

8

0.12 A/μs

12 A/ms

32 μs

9

0.25 A/μs

25 A/ms

16 μs

10

0.5

A/μs

0.05

A/μs

12 μs

11

1.2 A/μs

0.12

A/μs

12 μs

12

2.5 A/μs

0.25

A/μs

12 μs

 

*AC performance specified from 3 to 60 V.

Voltage Slew Rate:

 

 

Rate # Voltage Range Step

Transition Time*

1

1 V/ms

8.0 ms

2

2.5 V/ms

3.2 ms

3

5 V/ms

1.6 ms

4

10 V/ms

800 μs

5

25 V/ms

320 μs

6

50 V/ms

160 μs

7

0.1 V/μs

85

μs

8

0.25 V/μs

85

μS

9

0.5 V/μs

85

μS

*Transition time based on low capacitance current source.

Resistance Slew Rate (2 Ω range): Uses the value programmed for voltage slew rate.

Resistance Slew Rate (2 k and 10 kΩ ranges): Uses the value programmed for current slew rate.

Transient Current Overshoot (When programmed from 0A):

 

Range

Transient Current Level

 

 

Current Slew Rate

Overshoot*

30 A

3-30 A

All slew rates

0

 

1.5 A

0.5

A/μs to 2.5 A/μs

6%

 

1.5 A

0.5

A/ms to 0.25 A/μs

0

3 A

3 A

All slew rates

0

 

1.5 A

0.13

A/μs and 0.25 A/μs

3%

 

1.5 A

0.05

A/ms and 0.05 A/μs

0

*Overshoot may be higher during first five seconds of programming if unit has been operating at full current. Overshoot values assume a total inductance of lμH, or less, in the load leads connected to the D.U.T.

5

Image 7
Contents OPERATING MANUAL 150 WATT ELECTRONIC LOAD MODULE Agilent Model 60501BPrinted in U.S.A Manufacturer’s Name DECLARATION OF CONFORMITYaccording to ISO/IEC Guide 22 and EN Safety150-Watt Module Module Installation and OperationAbout This Manual Items SuppliedVoltage 3 to 60 V minimum dc operation from 0 to 2 V for 0 to 30 A 50 μs ± 3% minimum 4 s ± 3% maximum 6% of setting ± 2%0.25 Hz to 10 kHz 3% to 97% 0.25 Hz to 1 kHz 6% to 94% 1 kHz to 10 kHz10 kHz 3 db frequency Range CURRRANG value CRNG valueTable 60501-2. Programming Ranges continued Table 60501-3. Factory Default SettingsSettings SettingVariables Power Supply SettingsTable 60501-4. Calibration Information Ranges and Calibration PointsCanada Agilent Sales and Support OfficeUnited States Latin America
Related manuals