Thermador CGB30RCULP manual Read ALL Instructions Before Using Your Barbecue, Safety Precautions

Page 6

SECTION 1: SAFETY PRACTICES TO AVOID PERSONAL INJURY

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING YOUR BARBECUE

SAFETY PRECAUTIONS

When properly cared for, your new Thermador® Char Glo® barbecue has been designed to be a safe and reliable appliance. However, extreme care must be used as the grill produces intense heat and can increase the potential for accidents or injury. When using this appliance, basic safety precautions must be followed, including the following:

Read this manual carefully before using the barbecue to reduce the risk of fire, electric shock, or injury to persons.

Insure proper installation.Follow the instructions in Sections 3 through 5 in the Installation Instructions. Have the installer show you where the gas supply shutoff valve is located, and how to shut off the gas to the barbecue. Always adhere to the minimum clearances to combustible materials as specified in Section 3.

Do not repair or replace any part of this appliance unless specifically recommended in this manual. All other servicing should be referred to a qualified service technician.

If you smell gas when the unit is not in use, have the unit checked for leaks as defined in Section 4. Finding a gas leak is not a do-it-yourself procedure as some leaks can only be found with the burner control in the ON position. This must be done by a qualified technician.

This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Be aware that spiders and insects can nest in the burners of this barbecue. This can obstruct the proper flow of gas into the burner and cause improper operation, fire hazard and potential damage to the unit. Inspect the burners periodically, or immediately if any of the symptoms denoted in Section 8 exist.

The top cover (hood) is to be closed during the outdoor cooking gas appliance preheat period.

Never move barbecue with hood raised.

Keep hands and fingers away from all edges of the hood when it is in raised position.

WARNING: Never block vent opening at rear of hood. Use with the vent opening blocked will result in damage to the unit and may cause a fire or injury.

LP TANK REQUIREMENTS

Model CGB30RCULP is provided with an LP tank from the factory. All other units can be converted for use with an LP tank which can be purchased locally at a barbecue supply store or other retail outlet. The

If you smell gas when the unit is in use, immediately shut off all controls. Open the lid and let the gas dissipate for at least five minutes. Relight the burner(s) and verify that they are operating properly. If the burner(s) fail to relight or are not operating properly, shut of the gas to the unit and have the unit checked by a qualified service technician. See Section 9.

Children should not be left unattended in the area where the barbecue being used. Never allow children to sit, stand or play on or around the barbecue at any time. When in use, portions of the grill get hot enough to cause severe burns. Children should never be allowed to crawl inside the cart or enclosure.

To avoid the potential for a grease fire,frequently clean the drip tray. Be sure to let the unit cool completely before removing the tray for cleaning.

maximum tank capacity for use with Thermador® Char Glo® barbecues is twenty

pounds (five gallons). The tank must be constructed and marked in accordance with the specifications for LP-gas tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/ CSA-B339, tank, Spheres and Tubes for the Transportation of Dangerous Goods. To minimize the potential for fire or an explosion, the following precautions should be observed when using, filling or storing an LP tank:

Never use a dented or rusty LP tank. If there is any question as to the soundness of the tank, have it checked by your LP supplier.

Never use a tank with a damaged or defective shut off valve.

Always close the tank shut off valve after use.

Page 4

Image 6
Contents Care & Use Manual CGB30RCULP CGB36RU CGB48RU CGB48RSBUSpecial Message to Our Customers Table of Contents For Your Safety Avertissement’ILY a UNE Odeur DE GAZ Important Information Never move barbecue with hood raised Read ALL Instructions Before Using Your BarbecueSafety Precautions LP Tank RequirementsAvertissement For Your SafetyForyour Safety LP tank supply system must be arranged for vapor withdrawalModel and Parts Identification Model CGB48RSBU 1319Literature Pack Contents Model and Parts Identification Model CGB48RUAGA and CGA Approved Model CGB30RCULP Free Standing Front HoodInstallation of LP Propane GAS Tank A CGB36/48 LP Propane Lighting InstructionsModel and Parts Identification Model CGB36RU On front of hoodUsingyour Char GLO Barbecue If you smell gas, do not attempt to light any burnersBefore the First Use Lighting Instructions with Automatic Ignition Read Before LightingAccess Hole for Manual Lighting Manual Lighting InstructionsUsing the Grill Grill General Grill InformationUsing the Smoker General Smoker InformationUsing the Chart GrillFood Item Hens ChickenCornish Game LambInformation Rotisserie and AssemblyGeneral Rotisserie Arrange Food on the SkewerTrussing Poultry for the Rotisserie Temperature Gauge Side Shelf Extra Features General Side Burner InformationUsing the Side Burners Underside View of Side ShelfEasy Stainless Steel Maintenance Care and MaintenanceGrill ASSEMBLYReversible Quick Clean Method for GratesCleaning Chart Suggested CareTo Obtain Replacement Parts, order Service Before Phoning for ServiceTroubleshooting Service InformationWarranty Thermador Will Pay ForThermador Will Not Pay For