Regency IG34-LPG, IG34-ULPG, IG34-NG installation manual Operating Instructions

Page 23

OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass door is in place. Never operate the appliance with the door glass removed.

5)Verify that all flueing and the cap is unob- structed.

6)Verify log placement.

7)The unit should never be turned off and on again without a minimum of a 60 second wait.

8)When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fireplace for at least four (4) hours the first time you use it with the fan on.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: The main burner will always start on "HIGH" and resume it's last setting after 20 seconds of operation.

NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

DO NOT BURN THE APPLIANCE WITH- OUT THE GLASS FRONT IN PLACE.

SUMMARY OF

CONTROLS

On/Off Button

If the unit is switched off, pressing and releasing this button once will switch the unit on. The unit will resume its last settings.

If the unit is switched on, pressing and releasing this button once will switch the unit off.

Flame:

Increase - If the unit is switched on, pressing and releasing the flame plus (+) button once will increase the flame height to the next available high setting.

Decrease - If the unit is switched on, pressing and releasing the flame minus (-) button once will decrease the flame height to the next avail- able low setting.

Fan:

Increase - If the unit is switched on, pressing and releasing the fan plus (+) button once will increase the fan speed to the next available high setting.

Decrease - If the unit is switched on, pressing and releasing the fan minus (-) button once will decrease the fan speed to the next available low setting.

LIGHTING

INSTRUCTIONS

REMOTE CONTROL

FAN OPERATION

1)Plug the power cord into a power outlet.

2)Press and release the ON/OFF switch once to start the unit. The LED will be lit.

3)After approximately 8 seconds the spark ignition system will spark for 8 seconds to light the main burner.

4)If the main burner does not light, repeat step 2 to restart the unit.

SHUTDOWN

INSTRUCTIONS

1)Press the ON/OFF switch once.

2)The LED will flash.

3)Turn off all electric power to the appliance if service is to be performed.

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter and a wall mounting plate.

1)Choose a convenient location to mount the hand held transmitter, protection from extreme heat is very important.

By using the wall mounting plate to house the transmitter, the remote can also be used as a wall thermostat.

Set the fan speed on the control panel at the top rear of the unit to adjust to the desired speed.

Pressing and releasing the plus (+) FAN button will change the fan speed as follows:

OFF -> LOW -> MEDIUM -> HIGH -> OFF, etc.

Pressing and releasing the minus (-) FAN button will be the reverse of the above.

Fan must be running at all times when the unit is in operation.

ADJUSTING FLAME

HEIGHT

There are six flame settings that can be adjusted by pressing and releasing the plus (+) and minus (-) FLAME button.

Regency IG34 Gas Inbuilt Fireplace

23

Image 23
Contents Manual Regency GAS Inbuilt Fireplace Unit DimensionsTable of Contents Data Badge Regency Gas FireplaceInstallation GAS Connection Minimum Fireplace DimensionsClearances to Combustibles GAS Pipe Pressure Testing Flue Liner InstallationInstallation in Masonry or Zero Clearance Chimney System Data IG34 Aeration SettingsConversion Kit #486-968 for NG to LPG Model Cable Electric Modulator Conversion Kit #486-967 for NG to Ulpg Installation Before you start Optional Stainless Steel Inner Panel InstallLOG SET Installation D02-46 A02-43 C02-56 Place Front Left Log G02-44 onto the 2 front pins as shown Diagram Glass Door Installation Standard Flush DoorScreen Installation Faceplate & Optional Plinth Trim AssemblyFaceplate and Door Frame Installation Install faceplate and door frame as per previous Thermodisc InstallationFinal Check WiringOperating Instructions Normal Operating Sounds GAS Appliances Resetting the UnitCopy of Lighting Instruction Plate Door Glass Replacement MaintenanceMaintenance Instructions LOG ReplacementTo Remove Fan FAN MaintenanceValve Assembly Replacement Electronic Components Parts List Parts ListMain Assembly Faceplate Assembly Warranty Lifetime WarrantySouth LINK, Dandenong South Victoria Australia

IG34-LPG, IG34-NG, IG34-ULPG specifications

The Regency IG34 series comprises three innovative models: IG34-ULPG, IG34-NG, and IG34-LPG, designed to efficiently meet the demands of modern heating solutions. These gas fireplaces are distinguished by their commitment to energy efficiency, stunning aesthetics, and robust technology.

The IG34-ULPG model is tailored for users who prefer ultra-liquid propane gas options. This model stands out with its exceptional energy efficiency, capable of heating a significant area while minimizing environmental impact. Its sleek contemporary design features a large viewing window, allowing users to enjoy the beauty of the flames while providing warmth. With the advanced remote control technology, users can conveniently adjust settings from anywhere in the room.

On the other hand, the IG34-NG variant is optimized for natural gas users, offering similar efficiency and aesthetic advantages. It also boasts an impressive BTU output, ensuring that spaces remain cozy and inviting during cooler months. The user-friendly interface makes it easy to monitor and regulate the heat output, enhancing both comfort and convenience. One of the hallmark features of the IG34-NG is its state-of-the-art safety mechanisms, including an automatic shut-off system that ensures peace of mind when the unit is not in use.

The IG34-LPG model further extends the versatility of the series by being adaptable to both liquid propane and natural gas. This model is particularly popular among users who desire flexibility, as it can easily be converted from one fuel type to another with minimal effort. Additionally, the IG34-LPG incorporates modern combustion technologies that significantly reduce emissions, making it an environmentally friendly option without compromising performance.

Across the entire IG34 series, the fireplaces are engineered with premium materials ensuring durability and reliability. The direct vent system is a standout feature, allowing for efficient ventilation that minimizes heat loss while maintaining indoor air quality. Each model is equipped with a ceramic glass door that provides excellent thermal efficiency, ensuring that users enjoy maximum warmth without excessive energy expenditure.

In summary, the Regency IG34 series—IG34-ULPG, IG34-NG, and IG34-LPG—offers a compelling blend of efficiency, safety, and modern design. These fireplaces are not just heating solutions; they are lifestyle enhancements that provide comfort and elegance to any living space, making them a smart choice for homeowners seeking stylish and effective heating options.