MAINTENANCE

MAINTENANCE

INSTRUCTIONS

Any maintenance required accessing the glass door of the unit must be performed by an authorized service person.

1) Always unplug the power cord before

cleaning. For relighting, refer to lighting

instructions. Keep the burner and control

compartment clean by brushing and vacu-

uming at least once a year. When cleaning

the logs, use a soft clean brush as the logs

are fragile and easily damaged.

2) Clean glass (never when unit is hot), appli-

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLYSUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

LOG REPLACEMENT

The unit should never be used with broken logs. Unplug the power cord and allow the unit to cool before opening door to carefully remove the logs. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

Note: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

ance, louvres, and door with a damp cloth.

Never use an abrasive cleaner. The gold

louvres (and optional gold door) may be

scratched if abrasives are used to clean

them.

The heater is finished in a heat resistant

paint and should only be refinished with

heat resistant paint (not with wall paint).

Regency uses StoveBright Paint - Metallic

Black #6309.

3) Make a periodic check of burner for proper

position and condition. Visually check the

flame of the burner periodically, making sure

the flames are steady; not lifting or floating.

If there is a problem, call an authorized

service person.

4) The appliance and flueing system must be

inspected before use, and at least annu-

ally, by an authorized field service person,

to ensure that the flow of combustion and

ventilation air is not obstructed.

During the annual service call, the burners

should be removed from the burner tray

and cleaned. Replace the embers - do not

block the burner ports.

5) Keep the area near the appliance clear and

free from combustible materials, gasoline

and other flammable vapours and liquids.

6) Verify proper operation after servicing.

CAUTION: ANY SAFETY SCREEN ORGUARDREMOVEDFORSERV- ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT- ING THE APPLIANCE.

CLOTHING OR OTHER FLAM- MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL AN AUTHORIZED SERVICE TECHNI CIAN TO INSPECT THE APPLI- ANCE AND TO REPLACE ANY PART OF CONTROLSYSTEMAND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

DOOR GLASS

REPLACEMENT

Your Regency stove is supplied with high tem- perature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorised Regency dealer only, and follow our step-by-step instructions for replacement.

WARNING: do not operate appli- ance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or authorised service person.

Flush Glass Replacement

Slide old glass out of the side frames and replace with new glass.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-155).

Regency IG34 Gas Inbuilt Fireplace

25

Image 25
Contents Manual Regency GAS Inbuilt Fireplace Unit DimensionsTable of Contents Data Badge Regency Gas FireplaceInstallation Clearances to Combustibles Minimum Fireplace DimensionsGAS Connection GAS Pipe Pressure Testing Flue Liner InstallationInstallation in Masonry or Zero Clearance Chimney System Data IG34 Aeration SettingsConversion Kit #486-968 for NG to LPG Model Cable Electric Modulator Conversion Kit #486-967 for NG to Ulpg Installation Before you start Optional Stainless Steel Inner Panel InstallLOG SET Installation D02-46 A02-43 C02-56 Place Front Left Log G02-44 onto the 2 front pins as shown Diagram Glass Door Installation Standard Flush DoorScreen Installation Faceplate & Optional Plinth Trim AssemblyFaceplate and Door Frame Installation Install faceplate and door frame as per previous Thermodisc InstallationFinal Check WiringOperating Instructions Copy of Lighting Instruction Plate Resetting the UnitNormal Operating Sounds GAS Appliances Maintenance Instructions MaintenanceLOG Replacement Door Glass ReplacementTo Remove Fan FAN MaintenanceValve Assembly Replacement Electronic Components Parts List Parts ListMain Assembly Faceplate Assembly Warranty Lifetime WarrantySouth LINK, Dandenong South Victoria Australia

IG34-LPG, IG34-NG, IG34-ULPG specifications

The Regency IG34 series comprises three innovative models: IG34-ULPG, IG34-NG, and IG34-LPG, designed to efficiently meet the demands of modern heating solutions. These gas fireplaces are distinguished by their commitment to energy efficiency, stunning aesthetics, and robust technology.

The IG34-ULPG model is tailored for users who prefer ultra-liquid propane gas options. This model stands out with its exceptional energy efficiency, capable of heating a significant area while minimizing environmental impact. Its sleek contemporary design features a large viewing window, allowing users to enjoy the beauty of the flames while providing warmth. With the advanced remote control technology, users can conveniently adjust settings from anywhere in the room.

On the other hand, the IG34-NG variant is optimized for natural gas users, offering similar efficiency and aesthetic advantages. It also boasts an impressive BTU output, ensuring that spaces remain cozy and inviting during cooler months. The user-friendly interface makes it easy to monitor and regulate the heat output, enhancing both comfort and convenience. One of the hallmark features of the IG34-NG is its state-of-the-art safety mechanisms, including an automatic shut-off system that ensures peace of mind when the unit is not in use.

The IG34-LPG model further extends the versatility of the series by being adaptable to both liquid propane and natural gas. This model is particularly popular among users who desire flexibility, as it can easily be converted from one fuel type to another with minimal effort. Additionally, the IG34-LPG incorporates modern combustion technologies that significantly reduce emissions, making it an environmentally friendly option without compromising performance.

Across the entire IG34 series, the fireplaces are engineered with premium materials ensuring durability and reliability. The direct vent system is a standout feature, allowing for efficient ventilation that minimizes heat loss while maintaining indoor air quality. Each model is equipped with a ceramic glass door that provides excellent thermal efficiency, ensuring that users enjoy maximum warmth without excessive energy expenditure.

In summary, the Regency IG34 series—IG34-ULPG, IG34-NG, and IG34-LPG—offers a compelling blend of efficiency, safety, and modern design. These fireplaces are not just heating solutions; they are lifestyle enhancements that provide comfort and elegance to any living space, making them a smart choice for homeowners seeking stylish and effective heating options.