Regency IG34-ULPG Minimum Fireplace Dimensions, Clearances to Combustibles, GAS Connection

Page 6

INSTALLATION

MINIMUM FIREPLACE

DIMENSIONS

The minimum fireplace dimensions for the Regency gas space heater are shown in the following diagrams:

Mantel Clearances

FLUEING

THE APPLIANCE MUST NOT

BE CONNECTED TO A

CHIMNEY FLUE SERVING A

SEPARATE SOLID FUEL

BURNING APPLIANCE AND

MUST BE TERMINATED TO

THE OUTDOORS.

CLEARANCES TO

COMBUSTIBLES

Minimum Clearances to Combustibles

From Unit

 

Sides

A

10" / 255mm

Ceiling

B

47.5" / 1205mm

Mantel

C

13" / 330mm

Max. Mantle Depth

E

12" / 305mm

 

 

(see Dia. 2)

Min. Alcove Width

F

48" / 1220 mm

Max. Alcove Depth

G

36" / 915 mm

*No hearth required.

Note: A non-combustible mantel may be installed at a lower height if the fram- ing is made of metal studs covered with a non-combustible board.

GAS CONNECTION

GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry fireplace.

2)The appliance is provided with an opening on the right hand side of the control compartment. The 9.5mm (3/8") flexible gas hose provided needs to be brought in from behind this opening. Ensure all gas connections are tight.

3)Locate the center point where the vent will pass through the chimney above the appliance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.

This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney. The flue length must be a minimum length of 8 ' (2.44m) and a maximum of 35' (10.7m). See chart below for minimum distances from roof. Periodically check that the vent is unrestricted.

Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Part #

Description

948-305

 

76mm Flex - 10.6m

46dva-gk

Simpson Duravent Adaptor

46dva-vch

Simpson Vertical high wind cap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

L

Note: When installing the flueing, identify the flues.

Mark one exhaust and one intake as indicated on the top of the unit.

Gas

Inlet

6

Regency IG34 Gas Inbuilt Fireplace

Image 6
Contents Manual Unit Dimensions Regency GAS Inbuilt FireplaceTable of Contents Regency Gas Fireplace Data BadgeInstallation Minimum Fireplace Dimensions Clearances to CombustiblesGAS Connection Flue Liner Installation GAS Pipe Pressure TestingInstallation in Masonry or Zero Clearance Chimney Aeration Settings System Data IG34Conversion Kit #486-968 for NG to LPG Model Cable Electric Modulator Conversion Kit #486-967 for NG to Ulpg Installation Optional Stainless Steel Inner Panel Install Before you startLOG SET Installation D02-46 A02-43 C02-56 Place Front Left Log G02-44 onto the 2 front pins as shown Glass Door Installation Standard Flush Door DiagramFaceplate & Optional Plinth Trim Assembly Screen InstallationFaceplate and Door Frame Installation Thermodisc Installation Install faceplate and door frame as per previousWiring Final CheckOperating Instructions Resetting the Unit Copy of Lighting Instruction PlateNormal Operating Sounds GAS Appliances LOG Replacement MaintenanceMaintenance Instructions Door Glass ReplacementFAN Maintenance To Remove FanValve Assembly Replacement Parts List Electronic Components Parts ListMain Assembly Faceplate Assembly Warranty Warranty LifetimeSouth LINK, Dandenong South Victoria Australia

IG34-LPG, IG34-NG, IG34-ULPG specifications

The Regency IG34 series comprises three innovative models: IG34-ULPG, IG34-NG, and IG34-LPG, designed to efficiently meet the demands of modern heating solutions. These gas fireplaces are distinguished by their commitment to energy efficiency, stunning aesthetics, and robust technology.

The IG34-ULPG model is tailored for users who prefer ultra-liquid propane gas options. This model stands out with its exceptional energy efficiency, capable of heating a significant area while minimizing environmental impact. Its sleek contemporary design features a large viewing window, allowing users to enjoy the beauty of the flames while providing warmth. With the advanced remote control technology, users can conveniently adjust settings from anywhere in the room.

On the other hand, the IG34-NG variant is optimized for natural gas users, offering similar efficiency and aesthetic advantages. It also boasts an impressive BTU output, ensuring that spaces remain cozy and inviting during cooler months. The user-friendly interface makes it easy to monitor and regulate the heat output, enhancing both comfort and convenience. One of the hallmark features of the IG34-NG is its state-of-the-art safety mechanisms, including an automatic shut-off system that ensures peace of mind when the unit is not in use.

The IG34-LPG model further extends the versatility of the series by being adaptable to both liquid propane and natural gas. This model is particularly popular among users who desire flexibility, as it can easily be converted from one fuel type to another with minimal effort. Additionally, the IG34-LPG incorporates modern combustion technologies that significantly reduce emissions, making it an environmentally friendly option without compromising performance.

Across the entire IG34 series, the fireplaces are engineered with premium materials ensuring durability and reliability. The direct vent system is a standout feature, allowing for efficient ventilation that minimizes heat loss while maintaining indoor air quality. Each model is equipped with a ceramic glass door that provides excellent thermal efficiency, ensuring that users enjoy maximum warmth without excessive energy expenditure.

In summary, the Regency IG34 series—IG34-ULPG, IG34-NG, and IG34-LPG—offers a compelling blend of efficiency, safety, and modern design. These fireplaces are not just heating solutions; they are lifestyle enhancements that provide comfort and elegance to any living space, making them a smart choice for homeowners seeking stylish and effective heating options.