Regency IG34-NG, IG34-ULPG, IG34-LPG Flue Liner Installation, GAS Pipe Pressure Testing

Page 7

INSTALLATION

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

FLUE LINER

INSTALLATION

1)Cut the flex liner as required.

2)Mark the end of one liner to indicate Inlet.

3)Connect the other end of the above liner to the inlet side of the termination adaptor, seal connection with high temperature silicone. Secure with gear clamp.

4)Connect the 2nd liner to the exhaust side of the adaptor, seal connection with high temperature silicone. Secure with gear clamp.

Be careful not to damage thermal insula- tion when sliding on vent connector plate.

This could cause blockage.

9)Connect the 2nd liner to the exhaust collar marked with an "E", seal connection with high temperature silicone. Secure with gear clamp.

4)Seal and or check the pilot outlet (# 8)

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Screw should be snug, but do not over tighten.

S.I.T. Valve Description

1)On-Off Solenoid Valve EV1

2)On-Off Solenoid Valve EV2

3)Inlet Pressure Test Point

4)Outlet Pressure Test Point

5)Connection for Pressure Regulator/ Combustion Chamber Compensation

6)Pressure Regulator for Minimum and Maximum Outlet Pressure

7)Gas Outlet Pressure Electric Modulator

8)Pilot Outlet

9)Main Gas Outlet

10)Side Outlet

5)Install flashing.

6)Insert both liners into chimney, passing through the damper opening.

7)Install termination cap.

8)Connect the marked end of the liner to the inlet collar of the vent connector plate marked with an "I", seal connection with high temperature silicone. Secure with gear clamp.

Install to AS5601 (Australia) /

NZS 5262 (New Zealand)

GAS PIPE PRESSURE

TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 3.45 kPa (14" w.c.).

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" (# 3) and/or "OUT" (# 4) pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" (8mm) ID hose.

Regency IG34 Gas Inbuilt Fireplace

7

Image 7
Contents Manual Regency GAS Inbuilt Fireplace Unit DimensionsTable of Contents Data Badge Regency Gas FireplaceInstallation Clearances to Combustibles Minimum Fireplace DimensionsGAS Connection GAS Pipe Pressure Testing Flue Liner InstallationInstallation in Masonry or Zero Clearance Chimney System Data IG34 Aeration SettingsConversion Kit #486-968 for NG to LPG Model Cable Electric Modulator Conversion Kit #486-967 for NG to Ulpg Installation Before you start Optional Stainless Steel Inner Panel InstallLOG SET Installation D02-46 A02-43 C02-56 Place Front Left Log G02-44 onto the 2 front pins as shown Diagram Glass Door Installation Standard Flush DoorScreen Installation Faceplate & Optional Plinth Trim AssemblyFaceplate and Door Frame Installation Install faceplate and door frame as per previous Thermodisc InstallationFinal Check WiringOperating Instructions Copy of Lighting Instruction Plate Resetting the UnitNormal Operating Sounds GAS Appliances Door Glass Replacement MaintenanceMaintenance Instructions LOG ReplacementTo Remove Fan FAN MaintenanceValve Assembly Replacement Electronic Components Parts List Parts ListMain Assembly Faceplate Assembly Warranty Lifetime WarrantySouth LINK, Dandenong South Victoria Australia

IG34-LPG, IG34-NG, IG34-ULPG specifications

The Regency IG34 series comprises three innovative models: IG34-ULPG, IG34-NG, and IG34-LPG, designed to efficiently meet the demands of modern heating solutions. These gas fireplaces are distinguished by their commitment to energy efficiency, stunning aesthetics, and robust technology.

The IG34-ULPG model is tailored for users who prefer ultra-liquid propane gas options. This model stands out with its exceptional energy efficiency, capable of heating a significant area while minimizing environmental impact. Its sleek contemporary design features a large viewing window, allowing users to enjoy the beauty of the flames while providing warmth. With the advanced remote control technology, users can conveniently adjust settings from anywhere in the room.

On the other hand, the IG34-NG variant is optimized for natural gas users, offering similar efficiency and aesthetic advantages. It also boasts an impressive BTU output, ensuring that spaces remain cozy and inviting during cooler months. The user-friendly interface makes it easy to monitor and regulate the heat output, enhancing both comfort and convenience. One of the hallmark features of the IG34-NG is its state-of-the-art safety mechanisms, including an automatic shut-off system that ensures peace of mind when the unit is not in use.

The IG34-LPG model further extends the versatility of the series by being adaptable to both liquid propane and natural gas. This model is particularly popular among users who desire flexibility, as it can easily be converted from one fuel type to another with minimal effort. Additionally, the IG34-LPG incorporates modern combustion technologies that significantly reduce emissions, making it an environmentally friendly option without compromising performance.

Across the entire IG34 series, the fireplaces are engineered with premium materials ensuring durability and reliability. The direct vent system is a standout feature, allowing for efficient ventilation that minimizes heat loss while maintaining indoor air quality. Each model is equipped with a ceramic glass door that provides excellent thermal efficiency, ensuring that users enjoy maximum warmth without excessive energy expenditure.

In summary, the Regency IG34 series—IG34-ULPG, IG34-NG, and IG34-LPG—offers a compelling blend of efficiency, safety, and modern design. These fireplaces are not just heating solutions; they are lifestyle enhancements that provide comfort and elegance to any living space, making them a smart choice for homeowners seeking stylish and effective heating options.