TO 30,000 BTU/HR
INSTALLATION
Continued
CONNECTING TO GAS SUPPLY
NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an
_lb CAUTION: Use pipe joint seal-
ant that Is resistant to liquid pe- troleum (LP) gas.
Install sediment trap in supply line as shown in Figure 21. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture
and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
Supply Tank
Propane/LP
External
Regulator
Vent
Poirting
Down
•external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
20.Pointing the vent down protects it from freezing rain or sleet.
CAUTION: Use only new, black Iron or steel pipe. Inter-
or greater diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap,
Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21).
IMPORTANT: Hold pressure regulator
with wrench when connecting it to gas pip- ing and/or fittings.
Pressure
Regulator
3/8" NPT
FTee Joint
Test Reducer
Gauge ,_ Bushingto
Condition* I 1/8" NPT
11/8" NPT
L.PlugTap
Sediment I
Tr _ Fipe
ap
L Cap
Figure 21 - Gas Connection
Figure 20 - External RegulMor with Vent
Pointing Down
Note: Burnerbracket notshownfor clarity
Heater
Cabinet
Joint
Manual
-Shutoff Valve *
From External
Regulator (11"
W.C. to 14"W.C.
Pressure)
Minimum
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe could result in clogged heater valves.
*An A.G.A.
12 | fO4,U_ |