OBSERVED PROBLEM | POSSIBLE CAUSE |
|
| ||||
Heater produces | a clicking/ticking noise | 1. | Metal expanding while heating or con- | ||||
just after burner | is lit or shut off |
| tracting | while | cooling |
|
|
Heater produces | unwanted odors | 1. | Heater | burning | vapors | from paint, | hair |
|
|
| spray, glues, etc. (See IMPORTANT | ||||
|
|
| statement above) |
|
| ||
|
| 2. | Low fuel supply |
| at | ||
|
| 3. | Gas leak. SeeWaming | statement | |||
|
|
| top of page |
|
|
|
REMEDY
1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person
1.Ventilate room. Stop using odor caus- ing products while heater is running
2.Refill supply tank
3.Locate and correct all leaks (see Check- ing Gas Connections, page 13)
Heater shuts off in use (ODS operates) | 1. | Not | enough fresh air is available |
| 1. | Open window and/or door for ventilation | |||||||||
| 2. | Low | line pressure |
|
| 2. | Contact | local propane/LP | gas company | ||||||
| 3. | ODS/pilot is partially clogged |
| 3. | Clean |
| ODS/pilot | (see | Cleaning | and | |||||
|
|
|
|
|
|
| Maintenance, | page | 15) |
|
|
|
| ||
Gas odor even when control knob is in OFF | 1. | Gas leak. SeeWarnlng | statement | at | 1. | Locate | and correct all leaks | (see Check- | |||||||
position |
| top of page |
|
|
| ing Gas Connections, page 13) |
| ||||||||
| 2. | Control valve defective |
|
| 2. | Replace | control valve |
|
|
|
| ||||
Gas odor during combustion | 1. | Foreign matter between control valve | 1. | Take apart gas | tubing | and remove | for- | ||||||||
|
| and burner |
|
|
| eign matter |
|
|
|
|
|
| |||
| 2. | Gas leak. SeeWarnlng | statement | at | 2. | Locate | and correct all leaks | (see Check- | |||||||
|
| top of page |
|
|
| ing Gas Connections, page | 13) |
| |||||||
Moisture/condensation notieedonwiodows | 1. | Not enough combustion/ventilation | air. | 1. | Refer | to Air for Combustion | and Venti- | ||||||||
|
|
|
|
|
|
| lation | requirements | (page | 5) |
|
18 | la44_ |