Desa Tech RFP30T Specifications, Technical Service, Service Hints, Replacement Parts

Page 19

OWNER'S MANUAL

SPECIFICATIONS

BTU (Variable)

Type Gas

Ignition

Pressure Regulator Setting

Inlet Gas Pressure (in. of water) *

Maximum

Minimum

Dimensions, Inches (H x W x D)** Heater

Carton

Weight (pounds)

Heater

Shipping

•Forpurposesof input adjustment •*Measurementincludesknobsand hood.

TECHNICAL

SERVICE

You may have further questions about in- stallation, ol_ration, or troubleshooting.

If so, contact DESA International's Techni- cal Service Department at 1-800-323-5190.

15,000/30,000

Propane/LP Only

Piezo

8" W.C.

14"

11"

23.75x 25.9 x 8.5 26 x 27.75 x 10.25

29

35

SERVICE HINTS

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local prnpane/LP gas supplier.

REPLACEMENT

PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product. If they can't supply original replacement part(s), either contact your nearest Parts

Central (see below) or call DESA

International's Technical Service Depart- ment at 1-800-323-5190.

When calling DESA International, have ready:

your name

your address

model number of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If theycan 't supplyoriginal replacement part(s), either contact your nearestParts Central (page

20)or call DESA International's Parts De- partment at 1-800-972-7879 for referral in- formation.

When calling DESA International, have ready:

model number of your heater the replacement part number

_o44_

19

Image 19
Contents What to do if YOU Smell GAS Owners Operation and Installation ManualVENT-FREE PROPANE/LP GAS Radiant Flame Heater RFP30TGerous Safety InformationVENT-FREE PROPANE/LP Heater Poisoning may lead to death Carbon Monoxide Poisoning EarlyUnpacking Product FeaturesProduct Local CodesAssembling Heater AssemblyBrass Tdm AIR for Combustion and VentilationProviding Adequate Ventilation Assembling and Attaching Brass TrimTu/I-Ir AIR for Combustion VentilationDetermining Fresh AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceSpace Ventilation AIRVentilation Air From Inside Building To AtticLocating Heater InstallationInstallation Items BTU/HRThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsApplicable To Optional Mantel Owners ManualMounting Heater with Optional Hearth Base ifConnecting to GAS Supply Checking GAS Connections Pressure Testing Heater Gas ConnectionsRead Before For Your Safety I Lighting Operating HeaterControl To Turn OFF GASTo Appliance LightingInspecting Burner Cleaning MaintenanceCabinet Troubleshooting Clean burner see Cleaning and Mainte Observed Problem Possible Cause RemedyTop Observed ProblemReplacement Parts SpecificationsTechnical Service Service HintsParts Centrals Prestige Mantel AccessoriesIllustrated Parts Breakdown To oooo.TKEY NO. Part Number Parts ListModel Serial No Date Purchased Warranty InformationNot a UPC Osm8