Desa Tech RFP30T installation manual Assembly, Assembling Heater

Page 4

L 15,000

TO 30,000 BTU/HR

 

..T.

ASSEMBLY

ASSEMBLING HEATER

Tools Required:

Phillips Screwdriver

5/16" hex wrench

Slotted screwdriver

Removing Front Panel Of Heater

Piezo Ignitor

,Ignitor

Cable

1.Remove two screws near bottom cor-

ners of front panel with Phillips screw- driver.

2.Pull bottom of front panel forward, then down (see Figure 2).

Installing Log

Note: For easier installation, lay heater on its back.

1.Remove log from inside top of heater. Discard protective packaging.

2.Attach ignitor cable to piezo ignitor (see Figure 3).

3.With Phillips screwdriver, remove four

screws holding screen in place. Re-

move screen,

4.Gently slide log between log retaining brackets on deflector assembly (see Fig- ure 4). The log should fit firmly against bottom of log retaining brackets,

5.Reattach screen using four screws re- moved in step 3.

_b, WARNING: Always have burner shield and screen In place before operating heater.This pre- vents excessive temperatures on heater surfaces.

Failure to position the parts in accordance with these diagrams or failure to use only parts spe- cifically approved with this heater may result in property damage or personal Injury.

\.

Figure 2 - Removing Front Penel of Heater

Log

I

Screen J

FrontPanel

\

Truss

Head

Screw

Brass

Front Tdrn

Screw

Figure 4 - Assembling Heater

Attaching Brass Front Trim to Front Panel

1.Locate brass front trim in brass trim package.

2.Slide the head of two truss-heed screws from hardware packet into each end of brass front trim (see Figure 5).

3.Line up screws with boles in front panel (see Figure 4). Insert screws in holes. Attach nuts from inside of front panel. Tighten with wrench.

Figure 3 - A llachlng Ignitor Cable to Plezo

Ignitor

Heater Cabinet

Deflector

Log

Retaining

Brackets

_J

BumerShield

Screw

Brass Front

Trim

Nut

Truss-Head

Screw

Figure 5 - Attaching Brass Front Trim to Front Panel

4

104434

Image 4
Contents Owners Operation and Installation Manual VENT-FREE PROPANE/LP GAS Radiant Flame HeaterRFP30T What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP HeaterPoisoning may lead to death Carbon Monoxide Poisoning Early GerousProduct Features ProductLocal Codes UnpackingAssembly Assembling HeaterAIR for Combustion and Ventilation Providing Adequate VentilationAssembling and Attaching Brass Trim Brass TdmAIR for Combustion Ventilation Determining Fresh AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Tu/I-IrVentilation AIR Ventilation Air From Inside BuildingTo Attic SpaceInstallation Installation ItemsBTU/HR Locating HeaterThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Installing Bottom Mounting Screws Mounting Heater on Optional Hearth BaseOwners Manual Mounting Heater withOptional Hearth Base if Applicable To Optional MantelConnecting to GAS Supply Pressure Testing Heater Gas Connections Read Before For Your Safety I LightingOperating Heater Checking GAS ConnectionsTo Turn OFF GAS To ApplianceLighting ControlInspecting Burner Cleaning MaintenanceCabinet Troubleshooting Observed Problem Possible Cause Remedy Clean burner see Cleaning and MainteObserved Problem TopSpecifications Technical ServiceService Hints Replacement PartsParts Centrals Accessories Prestige MantelTo oooo.T Illustrated Parts BreakdownParts List KEY NO. Part NumberWarranty Information Not a UPCOsm8 Model Serial No Date Purchased