Care & Maintenance
Maintenance
BURNER ADJUSTMENT
NOTICE
It may be necessary to adjust the burners periodically, to compensate for variables in gas characteristics. If you notice the burner flame pat- tern is irregular (Refer to Figures 9a, 9b & 9c), it may be necessary to adjust the air shutter opening at the front of the venturi tubes.
•The shutters are accessible under the control panel at the front of the Grill. (Fig. 20)
•Use a screwdriver to loosen the locking screws. Open the shut- ter just enough to achieve the desired soft, blue flames. Make adjustments in small increments and allow the burner to come up to operating temperature (10 min.) before making further adjust- ments.
WARNING
Always allow sufficient time for the Grill to cool to a safe tempera- ture before handling or cleaning any of its components.
Figure 20
Loosen the
Locking Screw
Turn Shutter
Clockwise to Open
B139
If burners are removed for cleaning or adjustment, always confirm that they have been reinstalled correctly over the valve outlets. (Fig. 21) The valves should extend into the burner venturis 1/4” minimum.
NOTICE
Similar adjustment can be made to Rotisserie and/or Side Burners, if so equipped.
Figure 21
Venturi Tube
Valve Outlet
1/4” Minimum
B140
Page 21
50004425