Meco 7710S8.641, 7710.8.641 manual Troubleshooting Cont’d

Page 25

TROUBLESHOOTING (Cont’d)

Problem

Possible Cause

Solution

Burners will not light

 

LP-Excess flow valve tripped

using the ignitor

 

in regulator.

 

 

Vapor lock in connections.

 

 

 

 

 

Turn control knobs to “off” position and turn LP gas cylinder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at cylinder and grill. Disconnect the regulator from the LP gas cylinder. Reconnect the regulator to the LP gas cylinder. Perform a leak test. Relight grill. This will reset the excess flow valve.

Obstructions in burners

 

Clean the burners. (See How to Clean the burners in Care and

 

 

Maintenance.)

 

 

 

 

Wet Electrodes and burners

Wire loose or disconnected

Wire shorting (sparking between ignitor and electrode

Dry electrode with clean cloth. Air dry or use blow dryer.

Reconnect the wire.

Replace ignitor wire/electrode assembly (Call the Customer Service Department).

Burners will not light

Burners not assembled

using a match

correctly

 

LP-gas cylinder is empty

 

LP-Excess flow valve tripped

 

in regulator

See re-assembly after cleaning in Care and Maintenance.

Take LP gas cylinder to licensed LP gas supplier to be refilled

Turn control knobs to “off” position and turn LP gas cylinder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at cylinder and grill. Disconnect the regulator from the LP gas cylinder. Reconnect the regulator to the LP gas cylinder. Perform a leak test. Relight grill. This will reset the excess flow valve.

Regulator Coupling nut is not

Tighten coupling nut by hand about one-half to three quarters

fully connected to LP cylinder

turn. Do not use tools.

Obstructions in burners

See How to Clean the Burners in Care and Maintenance.

 

 

Low flame or low

LP-Gas in LP cylinder is low

Check LP gas cylinder. Refill if necessary.

 

heat

 

 

OR Natural Gas supply pressure is low

Excess flow valve tripped in regulator

Turn control knobs to “off” position and turn LP gas cylinder handle clockwise until it stops. Wait five minutes. Relight LP gas grill. If flame continues to be low, turn off gas at cylinder and grill. Disconnect the regulator from the LP gas cylinder. Reconnect the regulator to the LP gas cylinder. Perform a leak test. Relight grill. This will reset the excess flow valve.

Flames blow out

Flare up

Persistent grease fire

Unable to fill LP tank

High or gusting winds

Gas in LP cylinder is low

Excess flow valve tripped

Grease build up

Excessive fat in meat

Grease trapped around burner system

Some dealers have older fill nozzles with worn threads.

Turn front of grill away from wind or increase flame height.

Check LP gas cylinder. Refill if necessary.

See “Low flame” problem above.

Clean grill.

Trim fat from meat before grilling.

Turn control knobs “off” and turn handle of LP cylinder clock- wise until it stops. Open hood carefully and let fire burn out. After the grill cools, remove and clean all parts.

The worn nozzles don’t have enough “bite” to engage the valve. Try another licensed LP dealer.

25

Image 25
Contents Bushman LP Gas Grill Important Safeguards Page Carbon Monoxide Hazard Assembly InstructionsAssemble Fixed Leg Assemble Wheel Leg ToolsAssemble Cart Page Attach Bowl to Cart Attach Control Panel Attach Igniter WireMounting Hood/ Bowl Hinges Attach Hood Insert Flavor Activator Attach Hood Handle & Handle ShieldInsert Cooking Grid Insert Warming Rack Assemble Side Tables Install Privacy PanelSteel Fabric Version Insert Drip Cup GAS, CYLINDER, Hose Regulator Information Connecting/ Disconnecting LP Gas Cylinder to GrillLP Cylinder Precautions Before Using Your LP GAS GrillSelecting a Location Operating the LP GAS Grill Leak TestingPreparation Before Cooking Lighting the Grill Using IgniterManual Lighting of the Grill Check Your Flame End of Cooking Session Care and MaintenanceTurn off Your LP Gas Grill Grill CookingSpider Alert Burner Maintenance Cleaning the Grill Bowl Preventive Maintenance Flavor Activator Drip CupHardware List Emergencies Problem Possible Cause SolutionTroubleshooting Cont’d Important Notice This page intentionally left blank Meco Corporation Limited Warranty