Lynx Professional Grills L30PSR-1, L54PSFR-1, L54PSR-1 EleCtriCAl ConneCtions, ConneCTion To AC

Page 31

eleCtriCAl ConneCtions

warning - eleCtrICal g round I ng

Product installation must meet local electric codes or, in the absence of local codes, the latest

edition of the n ational e lectrical Code Ansi/nfPA n o. 70 or the Canadian e lectrical Code CgA 1.6b2005.

u se only a g round fault i nterrupter (gfi) protected circuit with this outdoor cooking gas ap- pliance.

I m Portant: when connecting your rotisserie motor, first connect the motor to the grill and then plug the grill into the outlet.

This grill is equipped with a three prong (grounding) electric plug for your protection against shock hazard and must be plugged directly into a properly grounded three prong outlet.

n EvER cut or remove the grounding prong from this plug.

Use only extension cords with a  prong grounding plug, rated for the power of the equip ment, and approved for outdoor use with a w-A” marking.

To protect against electric shock, do not immerse any part of the power cord, an extension cord or any plugs in water or other liquid.

Unplug the product from the outlet when not in use and before cleaning. Allow it to cool before putting on or taking off parts.

do not let the cord hang over the edge of a table or touch hot surfaces.

do not use an outdoor cooking gas appliance for purposes other than intended.

do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance malfunctions or has been damaged in any manner. contact the manufacturer for repair.

ConneCTion To AC

Installation requires an outdoor 120vAC 15A gfi (g round fault i nterrupter) electrical outlet adjacent to the grill.

The gfi outlet features an internal breaker that reduces shock hazard. This type of

outlet should be installed by a qualified electrician either inside the island enclosure for built-in units, or near the location where a free-standing unit will be used.

for built-in grills, the supplied 1 v transformer is connected

to the grill during installation.

If the electrical system fails to operate, a connection may have come loose in shipping or the gfi may have tripped, requiring a reset. See the Troubleshooting section for more details.

1

Image 31
Contents Make the Most of Your MessAge to our CustoMers… Dang Er L y a une odeur de gaz Dang Er If you smell gasLynx Professional g rills 5895 rickenbacker Commerce, Ca Ntents InstAllAtion guidelinesPage IMportAnt sAfety preCAutions Ort Osear rner For the rotIsserI e b Before eaChEleCtrIC Ign ItI on For the maI brass burne urRI ght most maI n burner Manual lI ghtI ngCold weather warn I ng Pro Pane Manual lI ghtI ng tubeDI reCt heat Pre-heatI ngNdI reCt heat ProSear Cleaning How To seArPreheatI ng the Prosear burner M otor He ro Stai n Less Steel CleAning your lynx grillDri P TrAy MAI n Brass BURn ERS To Clean the b rass b urnerRilling rACKs ERAm I c BriquettesProSear burner Yellow flame or gas smell wh I le Coo KI ng Troubleshooting your ly nx grillPlease check a few things before you call for service GrI ll wonWind h iTT ing g rill Low or I nsuffICI ent heatLigh Ts won’T ligh T Urner eXT inguishes only when seT To LowBurner eXT inguishes RoT isserie won’T ligh TUy-lynx CUS To M e sLynx Professional g rills II. limited five-year warranty Limited lifetime warrantyPage Final Checks Side Burner/LPSGE Hookup Wiring Schematics DeX leak Testing for further details Before you stArt BuilT- in insTAllAT ionsIMPorTAnT noT es ReAr hood C leArAn C e LeArAn C e To Co M Bustible mATERIALSPage NT erior PACKing UnpACking And AsseMblyRAT e & CArTon Ow to remove the CartonConneCTion To AC EleCtriCAl ConneCtionsNATurAl gAs GAs ConneCtionsLP Cylinder Equirements LP gAsLP Connections Leak test ProcedureTo adjust the burner low setting FinAl CheCksLynx technical s upport RAss b urner flAM e/ Air f low AdjusTM enTTo adjust One lAsT T hingCArT insTAllAT ion BuilT- in insTAllAT ionSide burner/lpsge hookup Wiring sCheMAtiCs L27 & L30 rotisserie Grill L36 & L42 rotisserie Grill L54 rotisserie Grill LynX ProfessionAl g rills eXP loded PArTs view 2010 Profession Al g rills PAr Maximum Runs for all Appliances on supply line Model-Specific BTU OutputsIndex Page Page