Page 34

lP Connections

Make sure the lP cylinder valve is fully closed. It is

finAl CheCks

possible for the valve to be open without releasing gas but, as soon as you start con necting the regulator, gas will leak from the connection.

Insert the regulator inlet into the cylinder valve and turn the black coupler clockwise until the coupler is hand tight. do not over-tighten this connec- tion.

To disconnect the coupler, first make sure the main cylinder valve is turned off. g rasp

the coupler and turn counter clockwise. The inlet will then

leAK TesT ing

danger!

To prevent fire or explosion hazard, DO NOT smoke or allow any potential source of ignition (sparks, electri cal arcing, etc) in the area while performing a leak test. Leak tests should be conducted outdoors only. Never conduct a leak test using fire or flame.

Wash off the soapy solution with cold water and dry.

Tighten the loose joint, or replace the faulty part with manufacturer-recommend- ed replacement parts.

do noT attempt to repair the l.P. cylinder valve if it is damaged. The only way to safely resolve a damaged cylinder is to re P lAC e i T.

Repeat the leak test to ensure that no leaks are present.

disengage.

Always leak-test the connec- tion after refilling or exchang- ing lP cylinders. (See I nd EX:

leak Test” for further details.)

gAs line Purging

You should purge the gas line of air before attempting to light the grill.

m ake sure all grill controls are in the “ off ” position.

Slowly turn on the main gas supply.

Push in the rotisserie knob and confirm that the igniter is glowing. It is furthest from the fuel source and will completely purge the lines. It will take several seconds for the burner to light.

h old the knob on for about 20 seconds to allow the air in the system to purge and the burner to light

wait at least 5 minutes after shutting off the control before attempting to light the burners.

leak test Procedure:

create a soapy solution of 1 part soap and  parts water.

Confirm that all control knobs are in the off position.

Turn on the fuel supply. for natural gas, turn the valve handle 1/4 turn to align with the gas flow.

for l.P., turn the cylinder valve knob counter clockwise one full rotation.

Apply the soap solution generously by paint brush or squirt bottle on all con nections and fittings.

If bubbles appear to

“grow” on any of the con- nections, you have a gas leak. I mm Ed IATELY turn off the gas supply.

fixing a gas leak

Shut off the gas supply

Turn all grill controls to the on ” position to purge

the grill of any gas build- up, then turn the controls back “ off ”.

low h eAT burner Ad- JUST m E nT

for maI n b rass burn- ers, Prosear™ and s I de burners!

do not adJ ust the ro-

tIsserI e burner

The main brass burners and side burners on your Lynx grill feature an adjustable low

setting.

f luctuations in gas pressure, gas conversion and even in the quality of the gas itself may affect burner perfor mance at the “ low” setting. It could be either too high or too low.

to adjust the burner low setting:

m ake sure the grill is cool.

Remove racks and briquette trays so that you can see the flames while adjusting the burners.

Light the burner and set it to “ low”. (all the way counter- clockwise).



Image 34
Contents Make the Most of Your MessAge to our CustoMers… Dang Er If you smell gas Dang Er L y a une odeur de gazLynx Professional g rills 5895 rickenbacker Commerce, Ca InstAllAtion guidelines NtentsPage IMportAnt sAfety preCAutions Ort Osear rner For the maI brass burne ur Before eaChEleCtrIC Ign ItI on For the rotIsserI e bManual lI ghtI ng tube Manual lI ghtI ngCold weather warn I ng Pro Pane RI ght most maI n burnerDI reCt heat Pre-heatI ngNdI reCt heat ProSear Cleaning How To seArPreheatI ng the Prosear burner M otor He ro Stai n Less Steel CleAning your lynx grillDri P TrAy ERAm I c Briquettes To Clean the b rass b urnerRilling rACKs MAI n Brass BURn ERSProSear burner GrI ll won Troubleshooting your ly nx grillPlease check a few things before you call for service Yellow flame or gas smell wh I le Coo KI ngLow or I nsuffICI ent heat Wind h iTT ing g rillRoT isserie won’T ligh T Urner eXT inguishes only when seT To LowBurner eXT inguishes Ligh Ts won’T ligh TUy-lynx CUS To M e sLynx Professional g rills Limited lifetime warranty II. limited five-year warrantyPage Final Checks Side Burner/LPSGE Hookup Wiring Schematics DeX leak Testing for further details Before you stArt BuilT- in insTAllAT ionsIMPorTAnT noT es LeArAn C e To Co M Bustible mATERIALS ReAr hood C leArAn C ePage Ow to remove the Carton UnpACking And AsseMblyRAT e & CArTon NT erior PACKingEleCtriCAl ConneCtions ConneCTion To ACGAs ConneCtions NATurAl gAsLP gAs LP Cylinder EquirementsFinAl CheCks Leak test ProcedureTo adjust the burner low setting LP ConnectionsOne lAsT T hing RAss b urner flAM e/ Air f low AdjusTM enTTo adjust Lynx technical s upportCArT insTAllAT ion BuilT- in insTAllAT ionSide burner/lpsge hookup Wiring sCheMAtiCs L27 & L30 rotisserie Grill L36 & L42 rotisserie Grill L54 rotisserie Grill LynX ProfessionAl g rills eXP loded PArTs view 2010 Profession Al g rills PAr Model-Specific BTU Outputs Maximum Runs for all Appliances on supply lineIndex Page Page