Lynx Professional Grills L27-2 manual Before you stArt, IMPorTAnT noT es, BuilT- in insTAllAT ions

Page 27

before you stArt

if shipMent Arrives dAMAged

vIs I ble loss or damage:

Be certain any visible damage to the carton is noted on freight bill or express receipt and signed by the person making delivery.

file C lAi M for dAMAges i MM ediATely, regardless of extent of damage.

ConCealed loss or damage:

If damage is unnoticed until the grill is unpacked, notify the transportation company or carrier im mediately and file a “concealed damage” claim with them. This should be done within (15) days of the date delivery is made to you. Be sure to hold on to the container for inspection. We cannot assume responsibility for damage or loss incurred in transit. (see indeX: “ o btaining service from lynx” for further details.)

warning

n ever install this product into a combustible enclosure without an insulated jacket. doing so could result in fire, property damage and personal injury.

n ever locate the grill under a roof or overhang, in a building, garage, shed or other such enclosed area.

n ever locate the grill under combustible construction.

Installation must conform with local codes or, in the absence of local codes, with either the n ational fuel g as Code, Ansi Z223.1/nf PA 54, n atural g as and propane i nstallation Code, CsA b 149.1, or Propane storage and h andling Code, b 149.2,

iMPorTAnT noT es:

where’s the wind?

When selecting a suitable location, consider important factors such as exposure to the wind and foot-traffic

patterns.

If you have a freestanding grill, position it so the prevail ing wind blows into the front control panel (at your back when grilling), supporting the proper front-to-rear airflow.

b uilt-in grills located in areas with prevailing winds should be protected by a wind barrier.

Winds hitting the back of the grill directly may cause problems, as well as wind

h ow long is your run?

Keep all gas supply lines as short as possible because gas lines lose pressure over distance and with each elbow and tee that is added. This drop in pressure affects grill performance. (See I nd EX:

g as s upply line runs” for further details.)

are you “on-the-level”?

Proper leveling during instal- lation is critical. A grill that is ut of level will cause erratic urner combustion and inef cient, uneven heating. A arpenter’s spirit level should

e used to level the grill both ront-to-back and side-to-side.

the floor is uneven or has a decided slope, re-leveling may be required each time you move a freestanding unit.

builT- in insTAllAT ions

The lynx b uilt- i n g rill is designed for easy installation into masonry enclosures.

27

Image 27
Contents Make the Most of Your MessAge to our CustoMers… Dang Er L y a une odeur de gaz Dang Er If you smell gasLynx Professional g rills 5895 rickenbacker Commerce, Ca Ntents InstAllAtion guidelinesPage IMportAnt sAfety preCAutions Ort Osear rner For the rotIsserI e b Before eaChEleCtrIC Ign ItI on For the maI brass burne urRI ght most maI n burner Manual lI ghtI ngCold weather warn I ng Pro Pane Manual lI ghtI ng tubePre-heatI ng DI reCt heatNdI reCt heat How To seAr ProSear CleaningPreheatI ng the Prosear burner M otor He ro CleAning your lynx grill Stai n Less SteelDri P TrAy MAI n Brass BURn ERS To Clean the b rass b urnerRilling rACKs ERAm I c BriquettesProSear burner Yellow flame or gas smell wh I le Coo KI ng Troubleshooting your ly nx grillPlease check a few things before you call for service GrI ll wonWind h iTT ing g rill Low or I nsuffICI ent heatLigh Ts won’T ligh T Urner eXT inguishes only when seT To LowBurner eXT inguishes RoT isserie won’T ligh TCUS To M e s Uy-lynxLynx Professional g rills II. limited five-year warranty Limited lifetime warrantyPage Final Checks Side Burner/LPSGE Hookup Wiring Schematics DeX leak Testing for further details BuilT- in insTAllAT ions Before you stArtIMPorTAnT noT es ReAr hood C leArAn C e LeArAn C e To Co M Bustible mATERIALSPage NT erior PACKing UnpACking And AsseMblyRAT e & CArTon Ow to remove the CartonConneCTion To AC EleCtriCAl ConneCtionsNATurAl gAs GAs ConneCtionsLP Cylinder Equirements LP gAsLP Connections Leak test ProcedureTo adjust the burner low setting FinAl CheCksLynx technical s upport RAss b urner flAM e/ Air f low AdjusTM enTTo adjust One lAsT T hingBuilT- in insTAllAT ion CArT insTAllAT ionSide burner/lpsge hookup Wiring sCheMAtiCs L27 & L30 rotisserie Grill L36 & L42 rotisserie Grill L54 rotisserie Grill LynX ProfessionAl g rills eXP loded PArTs view 2010 Profession Al g rills PAr Maximum Runs for all Appliances on supply line Model-Specific BTU OutputsIndex Page Page