Page 43
Image 43
OPTIONAL STAINLESS STEEL / BLACK ENAMEL

 

 

 

 

INSTALLATION

 

 

 

 

 

 

 

 

OPTIONAL STAINLESS STEEL / BLACK ENAMEL

 

 

PANEL INSTALLATION

 

 

 

 

 

 

 

Before installation, panels must be handled and cleaned as per instructions noted below:

 

 

 

 

 

 

 

 

 

 

Stainless Steel Panels

 

Black Enamel Panels

 

 

• Stainless panels must be inspected for scratches and dimples prior

• Black Enamel panels must be inspected for scratches and dimples

 

 

 

to installation. All claims to be recorded at this time.

prior to installation. All claims to be recorded at this time.

 

 

Claims for damage after installation will not receive consideration.

Claims for damage after installation will not receive consideration.

 

 

 

 

 

 

 

 

To protect the finish during installation and handling - cotton gloves

 

 

 

 

 

MUST be worn at all times while handling the panels (even when

 

 

 

 

 

removing protective coating).

 

 

 

 

 

 

 

 

 

•Stainless panels will discolor a little during normal operation.

• Black Enamel panels will discolor a little during normal operation. This

 

 

 

This is normal and should not be considered a defect.

is normal and should not be considered a defect.

 

 

 

 

 

 

 

 

 

*

All hand and finger marks MUST be cleaned off with a soft cloth and

*

All hand and finger marks MUST be cleaned off with a soft cloth. Use

 

 

 

a stainless steel cleaner. Most stainless steel cleaners leave a film/

an ammonia based cleaner (ie. glass cleaner) to remove any fingerprints

 

 

residue on the surface of the panels. Use an ammonia based cleaner

before applying heat to the unit.

 

 

(ie. glass cleaner) to remove this film before applying heat to the unit.

Failure to do this will result in burn stains on panels which you

 

 

Failure to do this will result in burn stains on panels which you

will be unable to remove. Not protected by product warranty.

 

 

will be unable to remove. Not protected by product warranty.

 

 

 

 

STAINLESS STEEL PANEL INSTALLATION

Note: Panels must be installed prior to the installation of the log set and vermiculite.

 

TOP

LEFT
BACK
RIGHT

 

Diagram 4

Diagram 1

1)Remove the heat deflector by removing the 2 screws securing the heat deflector to the top of the firebox (see Diagram 2).

3)Slide back panel in over burner - be careful not to scratch panel on back log tray, burner, or top panel when positioning.

Heat defl ector

Diagram 2

2)Loosen the 2 baffle screws - position the top panel inside the firebox shown in Diagram 4. Slide slots of top panel into position under loosened screws, retighten the screws.

Slots on Top Panel

Diagram 5

Diagram 3