Regency B36X Installation, Horizontal Terminations, RIGID PIPE VENTING ARRANGEMENTS 5

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 24
Image 24
RIGID PIPE VENTING ARRANGEMENTS (5" X 8")

INSTALLATION

HORIZONTAL TERMINATIONS

RIGID PIPE VENTING ARRANGEMENTS (5" X 8")

Vinyl Siding

Standoff (Optional)

Horizontal

Termination

Cap

Wall Thimble

Pipe Length

90o Elbow

Horizontal Termination Rigid Pipe Adaptor

 

Horizontal Termination

A

Top Vent - No Vertical Rise

 

• When venting with a 90° elbow directly

A

off the unit, must use 5" X 8" Astrocap™

Flex vent or approved Rigid Vent System

 

 

• Max. 3 ft. horizontal run

BRear Vent w/ Horizontal Termination

Can only use 5" x 8" venting

Max. 3ft. horizontal run

Vinyl Siding

Standoff (Optional)

Horizontal

Termination

Cap

Wall Thimble

Top Vent - No Vertical RisePipe Length

Rigid Pipe Adaptor

B

The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.

For horizontal terminations the Regency Direct Vent Flex System (see page 14) may be used for installations with a maximum continuous vent length of 3ft (0.9m).

Note: Must use optional rigid pipe adaptor (Part # 770-994) when using Rigid Pipe vent systems.

Maintain clearance to combustibles.

Horizontal vent must be supported every 3 feet.

Firestops are required at each floor level and whenever passing through a wall.

0

Horizontal (Feet)

2

4

6

8

Vertical Height (Feet)

12

10

8

 

1/4"(1.1m)-44Rigid

1/8"(1.0m)-42Flex

6

 

 

 

 

4

 

 

 

2

Max. 36”(0.9m)

 

 

 

 

 

0

 

 

 

Factory Setting - No Restrictor Required

Factory Setting - No Restrictor Required

24

Regency Bellavista™ B36X Gas Fireplace

Page 24
Image 24
Regency B36X Installation, Horizontal Terminations, RIGID PIPE VENTING ARRANGEMENTS 5, Top Vent - No Vertical Rise