Regency B36X Fan Installation, To Remove The Fan, 1Shut the power off, Diagram, Electrical

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 50
Image 50
1)Shut the power off.

INSTALLATION

Important: 120 Volt AC power is needed for the fan switch and blower. The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualified electrician prior to fan assembly being installed. The neutral (wider) slot of the polarized receptacle should be at the top.

Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.

1)Shut the power off.

2)Open the bottom louver. Remove the standard flush door.

FAN INSTALLATION

5)Slide the thermodisc/cover assembly into the bracket clip on the underside of the firebox. Check that no wire will touch the hot surfaces. Diagram 3 and 4.

6)Plug the fan power cord into the rear end of the receptacle box to provide the maximum clearance from the louvers.

*Ensure that there is no interference with the wires when the louver is closed and that no wire will touch the hot metal surfaces or sharp edges.

8)Secure the fan wires and power cord by attaching one of the adhesive backed wire holder clips (Part #910-199) onto the stove base. Use the second clip to bundle up the wires approximately 4" from the control box.

3) Turn the fan base on its side (with the base facing towards you) and then slide the fan in towards the rear of the unit. Turn the fan upright and slip it over the two mounting studs. Take care not to damage the insulation on the fan base. Ensure that the fan blades do not rub against the valve tubing.

Diagram 3

Diagram 1

 

Electrical

 

Receptacle

 

Push Fan down

Diagram 4

 

on mounting pins

7) Slide the the Fan control box

 

 

under the clip on the floor of the firebox.

 

(See Diagram 5)
Ground Lug

Plug fan power cord into rear receptacle.

Diagram 2

4)Connect fan ground cable to ground lug. Refer to wiring diagram.

Diagram 5

Clip

Diagram 6

Diagram 7

TO REMOVE THE FAN

1)Shut the power off.

2)Reverse the above instructions.

Note: The bearings are lubricated for life. Do not lubricate them. Make sure you vacuum the fan area on a regular basis.

IMPORTANT:

These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming out the fan blades and housing using a soft brush nozzle.

50

Regency Bellavista™ B36X Gas Fireplace

Page 50
Image 50
Regency B36X Fan Installation, To Remove The Fan, 1Shut the power off, Electrical, See Diagram, Ground Lug