INSTALLATION

12)Turn control knob to the “OFF” position.

13)Remove the black protection cap by hand from the hi-low knob (Fig.1).

18)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5).

19)Re-assemble the black protection cap (Fig. 6).

Fig.1

Cap

14)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

Red o-ring visible

Fig.5

LPG Configuration

Fig.2

15)Check that the screw is clean and if necessary remove dirt.

16)Flip the screw (Fig. 3).

Red O-ring

Fig.3

17)Using the Allen wrench as shown in

Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

Fig.6

20)Reverse steps 8 - 1.

21)Attach the label "This unit has been converted to LPG" near or on top of the serial # decal.

WARNING!

Also check that the pilot and main burner injectors are appropriate for the gas type.

22)Replace yellow "NG" label with red "LPG" label.

WARNING!

Do not over tighten the screw. Recommended to

grip the wrench by the short side.