INSTALLATION
RIGID PIPE VENTING SYSTEMS
Horizontal or Vertical Terminations
The minimum components required for a basic horizontal termination using 4" x
1Rigid Pipe Adaptor
1Reducer
190o Elbow
1Wall Thimble
1Length of pipe to suit wall thickness
1Horizontal Termination Cap
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
Vertical
A
ASTROCAP #
DIMENSIONS
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Vinyl Siding
Standoff (Optional)
B
Astrocap |
11”
(279mm)
11” (279mm)
Wall Thimble
Pipe Length
| Pipe Length |
| 90o Elbow |
| Pipe |
| Length |
| Reducer |
43” | (4” x |
(1092 mm) | Rigid Pipe Adaptor |
WARNING:
Do not combine venting components from different venting systems.
Exception: However, use of the AstroCapTM and FPI Riser is acceptable with all systems.
This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraVent Direct Vent, Selkirk
The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson
Regency Bellavista™ B36X Gas Fireplace | 25 |