Regency B36X Dc Sparker Installation, Installation of the DC Sparker, Piezo Ignitor

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 41
Image 41
DC SPARKER INSTALLATION

INSTALLATION

DC SPARKER INSTALLATION

Installation of the DC Sparker:

23)Locate the Piezo Ignitor situated at the right side of the valve assembly.

Piezo

Ignitor

24)Remove the Piezo Ignitor wire from the back of the Piezo Ignitor.

Ignitor

Wire

Piezo

Ignitor

25)Connect the ignitor wire from the Piezo to the DC sparker.

DC

Sparker

Ignitor

Wire

27)Plug the DC spark generator wires to the DC Sparker.

28)Remove the battery cover from the DC Sparker and install 1 - 'AA' battery in the DC Sparker and then install the DC Sparker to the floor of the unit, left of the valve assembly, with two Phillips screws.

DC Sparker Battery Replacement

1)Remove the battery cover from the DC Sparker - remove the AA battery.

26)Connect the DC spark generator wires to the SIT Valve. Secure with a phillips head screw as shown below.

2) Replace with a new 'AA' battery and reinstall battery cover.

DC Sparker

Generator Wires

Regency Bellavista™ B36X Gas Fireplace

41

Page 41
Image 41
Regency B36X Dc Sparker Installation, Installation of the DC Sparker, DC Sparker Battery Replacement, Piezo Ignitor