Regency B36X Maintenance, Removing Valve, Installing Valve, 1Shut off the gas supply, Orifice

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 57
Image 57
REMOVING VALVE

MAINTENANCE

REMOVING VALVE

1)Shut off the gas supply.

2)Remove the louvers

3)Open the flush door and remove the door. (See Pg. 47 for instructions)

4)Remove the logs.

5)Remove the burner/grate assembly by removing the 2 Phillips head screws.

Diagram 1: Remove the left and right screws.

6)Slide the burner assembly to the left to release it from the orifice, then lift it out.

Orifice
Diagram 2: Slide burner assembly to the left
and then remove.

7)Remove the 2 screws securing the rear log tray and lift out. Diagram 3

Diagram 3

8)Disconnect the inlet gas line. (see Diagram 4)

Diagram 4

9)Disconnect the wall switch wires from the valve. (see Diagram 5)

Diagram 5

10)Remove the 8 Phillips head screws securing the valve tray assembly in place (Diagram

6)and then lift the entire assembly out (Diagram 7).

Diagram 6

Diagram 7

Diagram 8

INSTALLING VALVE

1)Place new valve tray into position

2)Reinstall the 8 hold down screws.

3)Hook up the 2 TP and 2 TH wires to the ap- propriate connections on the valve.

4)Reinstall the rear log tray.

5)Install Burner/grate assembly

6)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

7)Fire up the unit temporarily

8)Check the manifold pressure.

9)Reinstall the logs and brick panels as needed.

10)Reinstall the door and replace the louvers.

11)Fire up the unit again and check for proper flame appearance and glow on logs.

Regency Bellavista™ B36X Gas Fireplace

57

Page 57
Image 57
Regency B36X Maintenance, Removing Valve, Installing Valve, 1Shut off the gas supply, Orifice, and then remove, Diagram