Regency B36X Installation, H1, HORIZONTAL VENTING WITH THREE 3 90O ELBOWS, RIGID PIPE 4 X 6 - 5/8

Models: B36X

1 64
Download 64 pages 45.68 Kb
Page 29
Image 29
HORIZONTAL VENTING WITH THREE (3) 90O ELBOWS

INSTALLATION

HORIZONTAL VENTING WITH THREE (3) 90O ELBOWS

(RIGID PIPE 4" X 6 - 5/8")

H1H1VERTICAL VENTING WITH THREE (3) 90O ELBOWS(RIGID PIPE 4" X 6 - 5/8")

V1

One 90o elbow = Two 45o elbows.

H

Manual background V

Option V

H

V + V1 H + H1

A)0' Min. 1' Max. 1' Min. 2' Max.

B)1' Min. 2' Max. 3' Min. 3' Max.

C)2' Min. 2' Max. 5' Min. 4' Max.

D)3' Min. 2' Max. 7' Min. 5' Max.

E)4' Min. 3 Max. 9' Min. 6' Max.

F)5' Min. 4' Max. 10' Min. 7' Max.

G)6' Min. 5' Max. 11' Min. 8' Max.

H)7' Min. 6' Max. 12' Min. 9' Max.

With these options, max. total pipe length is 30 feet with min. of 12 feet total vertical and max. 9 feet total horizontal.

Please note min. 1 foot between 90o elbows is required.

Vent Restrictor - Full Open/ No Restrictor Installed

Lengths do not include elbow indicated.

Must use reducer # 946-606 and rigid pipe adaptor #770-994.

VERTICAL VENTING WITH THREE (3) 90O ELBOWS

(RIGID PIPE 4" X 6 - 5/8")

V1

 

One 90o elbow = Two 45o elbows.

H1

H

V

 

 

 

 

 

 

 

Option

V

H + H1

V + V1

With these options, max.

 

 

 

A)

0' Min.

2' Max.

2' Min.

 

 

 

B)

1' Min.

2' Max.

3' Min.

total pipe length is 30 feet

 

 

 

with min. of 10 feet total

 

 

 

C)

2' Min.

3' Max.

4' Min.

 

 

 

vertical and max. 8 feet

 

 

 

D)

3' Min.

4' Max.

6' Min.

total horizontal.

 

 

 

E)

4' Min.

5' Max.

7' Min.

Please note min. 1 foot

 

 

 

F)

5' Min.

6' Max.

8' Min.

 

 

 

between 90o elbows is

 

 

 

G)

6' Min.

7' Max.

9' Min.

required.

 

 

 

H) 7' Min. 8' Max. 10' Min.

 

 

 

 

Vent Restrictor Set at 2" Opening

 

 

 

 

 

Lengths do not include elbow indicated.

 

 

 

 

Must use reducer # 946-606 and rigid pipe adaptor #770-994

 

 

 

Regency Bellavista™ B36X Gas Fireplace

 

 

 